J954M0DIFIED1IN150PSIFLGS

J954M0DIFIED1IN150PSIFLGS Steam Trap

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. J954M0DIFIED1IN150PSIFLGS specification

Flange Thickness
A measurement of the smallest dimension of a flange,in distinction from length or width.

0.562in.

Flange Outside Diameter
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.

4.250in.

Body Design
The design of the body of the item.

angle pattern

Material And Location
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.

steel body

Design Type
Indicates the design type of the item.

thermostatic

Flange Bolt Hole Diameter
The length of a straight line which passes through the center of the flange bolt hole,and terminates at the circumference.

0.625in.

Flange Bolt Hole Quantity
The number of bolt holes in the flange.

4

Maximum Steam Working Pressure
The maximum steam pressure at which the item is designed to operate.

150.0 pounds per square inch

Strainer
An indication of whether or not a strainer is included.

not included

Rated Capacity At Maximum Working Pressure
The rated capacity of the item at maximum working pressure.

not rated

Inlet/outlet Connection Similarity
An indication of whether or not the inlet and/or outlet connection(s) is identical.

identical

Inlet/outlet Connection Nominal Pipe Size
The value used to define the nominal diameter of the inlet and/or outlet connection pipe.

1.000in.

Inlet/outlet Connection Type
Indicates the type of inlet and/or outlet connection provided.

flanged

Flange Facing Type
Indicates the type of flange facing provided.

plain

Err Default
The length of a straight line which passes through the center of a flange bolt circle,and terminates at the circumference.

err default

Inlet/outlet Connection Thread Provision
An indication of whether or not the inlet and/or outlet connection is threaded.

unthreaded

Inlet Location In Relation To Installed Position
Indicates the location of the inlet in relation to the installed position of the item.

center side

Outlet Location In Relation To Installed Position
Indicates the location of the outlet in relation to the installed position of the item.

bottom end

Gage Glass
An indication of whether or not a gage glass is included.

not included

Nondefinitive Spec/std Data
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.

150 series and 2 type

Answers.

What quantity is this sold in?

1EA

What is the NSN for J954M0DIFIED1IN150PSIFLGS?

4730-00-499-2091

How is this classified for shipping?

Schedule B number: 8402900090
nmfc 130430
Parts for steam or other vapor generating boilers and super-heated water boilers, except heat exchangers

What's the federal classification of J954M0DIFIED1IN150PSIFLGS?

FSC 4730 ⁓ Hose, pipe, tube, lubrication, and railing fittings

Excluding air conditioning-heating fittings (fsc 4520); bituminized fiber and concrete fittings (fsc 5630); conduit boxes and fittings (fsc 5975); downspout fittings (fsc 5670); medical and surgical fittings (fsc 6515); laboratory fittings (fsc 6640); post caps and rail ends (fsc 5660); machine thread bushings and plugs (fsc 5365).

NSN 4730-00-499-2091 TRAP,STEAM

NIIN
004992091
NIIN Date
07/06/74
Schedule B
8402900090 
Name Code
04853
FIIG
T359-B
QUP
Historical Price
$270.13 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MILT960 Cage 81349

Major End Users Countries and entities

  • - Department of The Navy 

Availability for J954M0DIFIED1IN150PSIFLGS A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
85.0 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Construction materials: includes paint and related materials, prefabricated building, wood products, metal and composition mater 
Commodity (for shipments via water)
Metal and metal products, nos, (less than 35 feet) 
NMFC (national motor freight code)
130430 MACHINERY:STEAM TRAPS 
UFC (universal freight code)
65960 

Similar by Design Other traps with similar characteristics

Nothing similar to this part number was found in our inventory

J954M0DIFIED1IN150PSIFLGS / Trap,steamWhat is the formal definition of this item?

A device for allowing the passage of condensate, or of air and condensate, and for preventing the passage of steam.