Used on f100ge100 engine. 2.239" overall length 0.808 in. dia; wt .11 lbs max; spring retainer cap must withstand a min 15 in. lbs; removal torque; shall withstand magnetic strength using 40 g static load without actuation; prevents actuation below 120 deg f; permits actuation above 140 deg f; once actuated with the test fluid pressure released, the button shall withstand a 5 lb reset load without resetting
Used on 2915-01-314-0716 pump,fuel,metering f404 power plant. 2.360" overall length indicator device measures 1.620 in width; 0.940 in. height; reset button latches, when actuated (must be manually moved laterally to retract before indicator button can be reset)
Used on 2915-01-314-0716 pump,fuel,metering f404 power plant. 2.360" overall length indicator device measures 1.620 in. width, 0.940 in. height; reset button latches, when actuated (must be manually moved laterally to retract before indicator button can be reset)