M24236/2-JALFKG

M242362JALFKG Thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. M24236/2-JALFKG specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

3a single threaded bushing

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.394in. single threaded bushing and 0.414in. single threaded bushing ⁓27/64"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.670in. ⁓2-43/64"

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

0.670in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.170in.

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

immersion well

Width Across Flats
The shortest straight line between flats,perpendicular to the height.

0.940in. and 1.010in. ⁓1-1/64"

Operating Temp Rating
The temperature at which the item operates.

-75.0 deg fahrenheit and 500.0 deg fahrenheit

Mounting Method
The means of attaching the item.

threaded bushing

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

electrical box connector

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

16 single threaded bushing

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.750in. single threaded bushing ⁓3/4"

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, normally closed, momentary action

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

connector, receptacle

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

2.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage and 500.0 milliamperes lamp load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

5.0 amperes resistive load second voltage and 2.5 amperes inductive load second voltage and 1.0 amperes lamp load second voltage

Contact Adjustability
The adjustability of the contact.

deactuation point not adjustable and actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

165.00 actuation point degrees fahrenheit and 145.00 deactuation point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

28.0 dc at sea level second voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 first voltage

Media For Which Designed
The type of media for which the item is designed.

gas or liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical w/flange

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-S-24236 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf single threaded bushing

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-S-24236/2 government specification

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unf single threaded bushing

What is the style?

Cylindrical w/flange

What is the thread quantity per inch?

16 single threaded bushing

What is the thread length?

0.394 inches minimum single threaded bushing and 0.414 inches maximum single threaded bushing

What is the thread class?

3a single threaded bushing

What is the NSN for M24236/2-JALFKG?

5930-01-157-9583

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of M24236/2-JALFKG?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-157-9583 SWITCH,THERMOSTATIC

unf single threaded bushing thread series cylindrical w/flange 16 single threaded bushing thread quantity per inch 2.670" overall length 0.394" single threaded bushing thread length 3a single threaded bushing thread class

NIIN
011579583
NIIN Date
07/14/83
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$3,660.30 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MIL-PRF-24236/2 Cage 81349
2. MIL-S-24236/2 Cage 81349
3. 10135360 Cage A486G
4. MIL-S-24236/2 Cage 81349
5. 10135360 Cage A486G
6. MIL-PRF-24236/2 Cage 81349
7. MIL-S-24236/2 Cage 81349
8. 10135360 Cage A486G
9. MIL-PRF-24236/2 Cage 81349
10. MIL-S-24236/2 Cage 81349
11. 10135360 Cage A486G
12. MIL-PRF-24236/2 Cage 81349
13. MIL-S-24236/2 Cage 81349
14. 10135360 Cage A486G

Major End Users Countries and entities

  • - Department of The Navy 
  • - Finland 
  • - Spain 
  • - Australia 
  • - Canada 

Availability for M24236/2-JALFKG A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

M24236/2-JALFKG / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).