Serving our customers with quality and safety first.
2a single threaded stud
0.185in. single threaded stud and 0.192in. single threaded stud ⁓13/64"
vibration resistant
0.732in.
0.437in.
0.540in. and 0.640in. ⁓41/64"
internal sensor
-65.0 deg fahrenheit and 500.0 deg fahrenheit
threaded stud
hermetically sealed case
32 single threaded stud
increase
0.138in. single threaded stud ⁓9/64"
1 pole, single throw, normally closed, momentary action
tab, solder lug
2.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage and 0.5 amperes lamp load first VOLTAGE5.0 amperes resistive load second voltage and 2.5 amperes inductive load second voltage and 1.0 amperes lamp load second voltage
actuation point not adjustable and deactuation point not adjustable
170.00 actuation point degrees fahrenheit and 150.00 deactuation point degrees fahrenheit
115.0 ac at sea level first VOLTAGE28.0 dc at sea level second voltage
60.0 first voltage
gas or liquid
disc
81349-MIL-S-24236 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
unc single threaded stud
81349-MIL-S-24236/1 government specification
1EA
Unc single threaded stud
Disc
32 single threaded stud
0.185 inches minimum single threaded stud and 0.192 inches maximum single threaded stud
2a single threaded stud
Schedule B number: 9032100000
nmfc 061300
Thermostats
FSC 5930 ⁓ Switches
Excluding switchgear.
unc single threaded stud thread series disc 32 single threaded stud thread quantity per inch 0.185" single threaded stud thread length 2a single threaded stud thread class
1. | MIL-PRF-24236/1 | Cage 81349 |
2. | MIL-S-24236/1 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).