AB008-10

AB00810 Thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. AB008-10 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

3a single threaded hole

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.875in. ⁓4-7/8"

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

internal sensor

Width Across Flats
The shortest straight line between flats,perpendicular to the height.

1.375in. ⁓1-3/8"

Mounting Method
The means of attaching the item.

bolt

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.500in. single threaded hole ⁓1/2"

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, normally closed, momentary action

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

wire lead

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

5.0 amperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

25.00 actuation point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

125.0 ac at sea level single voltage

Media For Which Designed
The type of media for which the item is designed.

liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf single threaded hole

Answers.

What class is the thread series?

Unf single threaded hole

What is the style?

Cylindrical

What is the thread class?

3a single threaded hole

What is the NSN for AB008-10?

5930-01-484-7042

How is this classified for shipping?

Schedule B number: 9032100000
Thermostats

What's the federal classification of AB008-10?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-484-7042 SWITCH,THERMOSTATIC

unf single threaded hole thread series cylindrical 4.875" overall length 3a single threaded hole thread class

NIIN
014847042
NIIN Date
05/04/01
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Italy 

Availability for AB008-10 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

AB008-10 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).