Serving our customers with quality and safety first.
1.240in. and 1.260in. ⁓1-17/64"
0.526in.
0.605in.
0.390in.
0.937in.
internal sensor
bracket
hermetically sealed case
increase
two position IN-Line
1 pole, single throw, normally closed, momentary action
tab, solder lug
2.0 amperes resistive load second voltage
3.0 amperes resistive load third voltage
1.0 amperes resistive load first voltage
deactuation point not adjustable and actuation point not adjustable
195.00 actuation point degrees fahrenheit and 180.00 deactuation point degrees fahrenheit
115.0 ac at sea level second voltage
250.0 ac at sea level first voltage
30.0 dc at sea level third voltage
incl evacuation tube
60.0 single voltage
gas
disc w/flange
81349-MIL-S-24236 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
1EA
Disc w/flange
Schedule B number: 9032100000
nmfc 061300
Thermostats
FSC 5930 ⁓ Switches
Excluding switchgear.
disc w/flange incl evacuation tube 1.240" overall length
1. | 975-0282-014 | Cage 97896 |
2. | 1041-50-435..980 | Cage 4G0W8 |
3. | 11041-50-435..980 | Cage 4G0W8 |
4. | 975-0282-001 | Cage 97896 |
5. | 975-0282-14 | Cage 97896 |
6. | 1041-50-435..980 | Cage 82647 |
7. | 11041-50-435..980 | Cage 82647 |
Nothing similar to this part number was found in our inventory
A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).