91316447

91316447 Thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 91316447 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.343in. ⁓4-11/32"

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

0.618in. and 0.625in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

3.718in.

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

4920-01-092-3114

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

internal sensor

Mounting Method
The means of attaching the item.

clamp

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, normally open, momentary action

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

wire lead

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

2.0 amperes resistive load fourth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

2.0 amperes resistive load third voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

10.0 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

5.0 amperes resistive load first voltage

Contact Adjustability
The adjustability of the contact.

deactuation point adjustable, preset and actuation point adjustable, preset

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

-100.00/+400.00 actuation point degrees fahrenheit and -100.00/+400.00 deactuation point degrees fahrenheit

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

external deactuation point screw and external actuation point screw

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

21.00 actuation point degrees fahrenheit and 16.00 deactuation point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 dc at sea level third voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

120.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

240.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

28.0 dc at sea level fourth voltage

Media For Which Designed
The type of media for which the item is designed.

gas or liquid

Answers.

What quantity is this sold in?

1EA

What is the NSN for 91316447?

5930-01-123-0609

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of 91316447?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-123-0609 SWITCH,THERMOSTATIC

Used on 4920-01-092-3114. 4.343" overall length

NIIN
011230609
NIIN Date
12/05/81
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
Item Weight
0.300lbs
Item Dimensions
60 X 20 X 20
QUP
Historical Price
$528.08 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 17021-0 Cage 73168
2. 91388366 Cage F6481
3. 17021-0-21F Cage 0KDP7
4. 806963-1 Cage 96214
5. 17021-0-21F Cage 73168

Major End Users Countries and entities

  • - Department of The Air Force 
  • - Department of The Navy 
  • - France 

Availability for 91316447 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

91316447 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).