Datasheet. 640017-7 specification

Longest Horizontal Distance Between Mounting Centers
The longest distance between mounting centers parallel to the horizontal plane.

1.010in.

Mounting Method
The means of attaching the item.

bracket

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, both positions maintained

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

tab, solder lug

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

1.0 amperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

deactuation point not adjustable and actuation point adjustable, preset

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

-20.00/+175.00 actuation point degrees fahrenheit

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

external actuation point screw

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

6.00 differential point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 ac at sea level single voltage

Media For Which Designed
The type of media for which the item is designed.

gas or liquid

Answers.

What quantity is this sold in?

1EA

What is the NSN for 640017-7?

5930-00-864-7712

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of 640017-7?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-864-7712 SWITCH,THERMOSTATIC

NIIN
008647712
NIIN Date
01/01/63
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
QUP
Historical Price
$24.00 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 32410-175 Cage 73168

Major End Users Countries and entities

  • - New Zealand 

Availability for 640017-7 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

640017-7 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).