1.180in. ⁓1-3/16"
0.380in.
0.605in.
0.140in.
0.290in.
0.140in.
0.937in.
disc
-80.0 deg fahrenheit and 550.0 deg fahrenheit
bracket and unthreaded hole and slot
hermetically sealed case
increase
two position IN-Line
1 pole, single throw, normally closed, momentary action
tab, solder lug
3.0 amperes resistive load second voltage
6.0 amperes resistive load first voltage
7.0 amperes resistive load third voltage
actuation point adjustable, preset and deactuation point not adjustable
-20.00/+500.00 actuation point degrees fahrenheit
internal actuation point screw
55.00 actuation point degrees fahrenheit and 65.00 actuation point degrees fahrenheit and 35.00 deactuation point degrees fahrenheit and 45.00 deactuation point degrees fahrenheit
120.0 ac at sea level first voltage
240.0 ac at sea level second voltage
30.0 dc at sea level third voltage
gas or liquid
disc w/flange
1EA
Disc w/flange
Schedule B number: 9032100000
nmfc 061300
Thermostats
FSC 5930 ⁓ Switches
Excluding switchgear.
disc w/flange 1.180" overall length
1. | 3100U-3-1433 | Cage 14604 |
Nothing similar to this part number was found in our inventory
A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).