3153-53-7

3153537 Thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 3153-53-7 specification

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.325in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

0.247in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

0.686in. ⁓11/16"

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.147in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

0.437in.

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

internal sensor

Operating Temp Rating
The temperature at which the item operates.

-54.0 deg celsius and 177.0 deg celsius

Mounting Method
The means of attaching the item.

bracket and unthreaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

hermetically sealed case

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, both positions maintained

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

tab, solder lug

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

1.5 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

4.0 amperes resistive load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

6.0 amperes resistive load third voltage

Contact Adjustability
The adjustability of the contact.

actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

110.00 actuation point degrees celsius and 106.00 deactuation point degrees celsius

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

120.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

240.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

30.0 dc at sea level third voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 first voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 second voltage

Media For Which Designed
The type of media for which the item is designed.

gas

Precious Material And Location
An indication of the precious material and its location in the item.

contacts gold

Precious Material
Identification of the precious material contained in the item.

gold

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

disc

Answers.

What quantity is this sold in?

1EA

What is the style?

Disc

What is the NSN for 3153-53-7?

5930-01-210-7208

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of 3153-53-7?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-210-7208 SWITCH,THERMOSTATIC

disc

NIIN
012107208
NIIN Date
06/16/85
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$353.90 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains gold
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 202688-001 Cage 81413

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 3153-53-7 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

3153-53-7 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).