1513586

1513586 Thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 1513586 specification

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.750in. single threaded bushing ⁓3/4"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.450in. ⁓3-29/64"

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.640in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

2.160in. ⁓2-11/64"

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

C-5, B-52 aircraft support equipment. shipboard material handling equipment (mhe) .

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

bulb

Mounting Method
The means of attaching the item.

line

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.500in. single threaded bushing ⁓1/2"

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, normally open, momentary action

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

threaded stud

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

6.0 amperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

240.00 actuation point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

14.5 dc at sea level single voltage

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

weapon system essential

Media For Which Designed
The type of media for which the item is designed.

liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

nptf single threaded bushing

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Nptf single threaded bushing

What is the style?

Cylindrical

What is the thread length?

0.750 inches single threaded bushing

What is the NSN for 1513586?

5930-00-718-7075

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of 1513586?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-718-7075 SWITCH,THERMOSTATIC

Used on c-5, b-52 aircraft support equipment. shipboard material handling equipment (mhe).. nptf single threaded bushing thread series cylindrical weapon system essential 3.450" overall length 0.750" single threaded bushing thread length

NIIN
007187075
NIIN Date
01/01/61
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
Item Weight
0.500lbs
Item Dimensions
--
QUP
Historical Price
$1,103.58 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 48641 Cage 5RQL2
2. 48641 Cage 16004

Major End Users Countries and entities

  • - Department of The Air Force 
  • - Department of The Army 
  • - Department of The Navy 

Availability for 1513586 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

1513586 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).