Datasheet. 02-7113472 specification

Hazardous Locations/environmental Protection
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.

dustproof

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.160in. ⁓4-11/64"

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.900in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

1.250in. ⁓1-1/4"

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

2320-01-113-3616 chassis truck

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

immersion well

Operating Temp Rating
The temperature at which the item operates.

-40.0 deg fahrenheit and 250.0 deg fahrenheit

Mounting Method
The means of attaching the item.

threaded bushing

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

18 single threaded bushing

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.375in. single threaded bushing ⁓3/8"

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

tab w/screw

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

10.0 amperes resistive load and 5.0 amperes inductive load and 3.0 amperes lamp load single voltage

Contact Adjustability
The adjustability of the contact.

actuation point not adjustable and deactuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

204.00 actuation point degrees fahrenheit and 210.00 deactuation point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

30.0 dc at sea level single voltage

Media For Which Designed
The type of media for which the item is designed.

liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

npt single threaded bushing

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Npt single threaded bushing

What is the style?

Cylindrical

What is the thread quantity per inch?

18 single threaded bushing

What is the NSN for 02-7113472?

5930-01-212-5407

How is this classified for shipping?

Schedule B number: 9032100000
nmfc 061300
Thermostats

What's the federal classification of 02-7113472?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-212-5407 SWITCH,THERMOSTATIC

Used on 2320-01-113-3616 chassis truck. npt single threaded bushing thread series cylindrical 18 single threaded bushing thread quantity per inch 4.160" overall length

NIIN
012125407
NIIN Date
07/13/85
Schedule B
9032100000 
Name Code
00451
FIIG
A048B0
Item Weight
0.300lbs
Item Dimensions
--
QUP
Historical Price
$160.68 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 1002-04870-34 Cage 51377

Major End Users Countries and entities

  • - Department of The Army 
  • - Department of The Air Force 
  • - Department of The Navy 
  • - U.s. Coast Guard 
  • - New Zealand 

Availability for 02-7113472 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

02-7113472 / Switch,thermostaticWhat is the formal definition of this item?

A switch that is actuated by changes in ambient temperature. excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. see also control, temperature (as modified) and regulator, temperature (as modified).