Serving our customers with quality and safety first.
not established
solder
1.500in.
0.585in.
0.200in.
0.025in.
250.00 milliwatts
100.0 deg celsius
150.0 deg celsius
60.0
250.0
0.70
-25.0 deg celsius 4th RESISTANCE-Temperature point
-50.0 deg celsius 3rd RESISTANCE-Temperature point
-75.0 deg celsius 1st RESISTANCE-Temperature point
-65.0 deg celsius 2nd RESISTANCE-Temperature point
0.0 deg celsius 5th RESISTANCE-Temperature point
100.0 deg celsius 8th RESISTANCE-Temperature point
125.0 deg celsius 9th RESISTANCE-Temperature point
150.0 deg celsius 10th RESISTANCE-Temperature point
50.0 deg celsius 6th RESISTANCE-Temperature point
75.0 deg celsius 7th RESISTANCE-Temperature point
277.2 ohms 5th RESISTANCE-Temperature point
386.1 ohms 6th RESISTANCE-Temperature point
455.4 ohms 7th RESISTANCE-Temperature point
528.0 ohms 8th RESISTANCE-Temperature point
627.0 ohms 9th RESISTANCE-Temperature point
696.3 ohms 10th RESISTANCE-Temperature point
158.4 ohms 1st RESISTANCE-Temperature point
171.6 ohms 2nd RESISTANCE-Temperature point
191.4 ohms 3rd RESISTANCE-Temperature point
231.0 ohms 4th RESISTANCE-Temperature point
-10.1/+10.1 10th RESISTANCE-Temperature point
-5.3/+5.3 5th RESISTANCE-Temperature point
-6.6/+6.6 6th RESISTANCE-Temperature point
-7.2/+7.2 7th RESISTANCE-Temperature point
-6.7/+6.7 4th RESISTANCE-Temperature point
-8.0/+8.0 2nd RESISTANCE-Temperature point
-7.4/+7.4 3rd RESISTANCE-Temperature point
-8.5/+8.5 8th RESISTANCE-Temperature point
-8.3/+8.3 1st RESISTANCE-Temperature point
-9.2/+9.2 9th RESISTANCE-Temperature point
encapsulated
0.014 cubicin.
330.000 ohms
-5.0/+5.0
100.0
0.500 grams
rod
3 wire lead
1EA
Rod
Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers
FSC 5905 ⁓ Resistors
Excluding resistance wire.
rod
1. | TM1/4 330OHMSPORM5PCT | Cage 50507 |
2. | TM1/4 330OHMSPORM5PCT | Cage 01295 |
Nothing similar to this part number was found in our inventory
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.