Serving our customers with quality and safety first.
not established
1.200in.
0.270in. and 0.300in.
0.090in. and 0.110in.
0.020in.
250.00 milliwatts
25.0 deg celsius
125.0 deg celsius
60.0
2.5
-15.0 deg celsius 2nd RESISTANCE-Temperature point
-55.0 deg celsius 1st RESISTANCE-Temperature point
0.0 deg celsius 3rd RESISTANCE-Temperature point
100.0 deg celsius 5th RESISTANCE-Temperature point
125.0 deg celsius 6th RESISTANCE-Temperature point
75.0 deg celsius 4th RESISTANCE-Temperature point
3.2 kilohms 4th RESISTANCE-Temperature point
3.7 kilohms 5th RESISTANCE-Temperature point
4.3 kilohms 6th RESISTANCE-Temperature point
1.1 kilohms 1st RESISTANCE-Temperature point
1.6 kilohms 2nd RESISTANCE-Temperature point
2.7 kilohms 3rd RESISTANCE-Temperature point
-12.0/+12.0 3rd RESISTANCE-Temperature point
-14.0/+14.0 2nd RESISTANCE-Temperature point
-14.0/+14.0 4th RESISTANCE-Temperature point
-17.0/+17.0 5th RESISTANCE-Temperature point
-20.0/+20.0 6th RESISTANCE-Temperature point
-20.0/+20.0 1st RESISTANCE-Temperature point
hermetically sealed
0.002 cubicin.
2.200 kilohms
-10.0/+10.0
rod
81349-MIL-R-23648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
2 wire lead
81349-MIL-R-23648/19 government specification
1EA
Rod
Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers
FSC 5905 ⁓ Resistors
Excluding resistance wire.
rod
1. | MIL-T-23648/19 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.