Serving our customers with quality and safety first.
not established
1.250in.
0.410in.
0.140in.
0.025in.
500.00 milliwatts
25.0 deg celsius
125.0 deg celsius
60.0
5.0
0.55
-15.0 deg celsius 2nd RESISTANCE-Temperature point
-55.0 deg celsius 1st RESISTANCE-Temperature point
100.0 deg celsius 5th RESISTANCE-Temperature point
125.0 deg celsius 6th RESISTANCE-Temperature point
50.0 deg celsius 3rd RESISTANCE-Temperature point
75.0 deg celsius 4th RESISTANCE-Temperature point
58.2 ohms 1st RESISTANCE-Temperature point
77.0 ohms 2nd RESISTANCE-Temperature point
117.0 ohms 3rd RESISTANCE-Temperature point
137.0 ohms 4th RESISTANCE-Temperature point
158.4 ohms 5th RESISTANCE-Temperature point
180.0 ohms 6th RESISTANCE-Temperature point
-12.0/+12.0 5th RESISTANCE-Temperature point
-15.0/+15.0 6th RESISTANCE-Temperature point
-15.0/+15.0 1st RESISTANCE-Temperature point
-7.0/+7.0 3rd RESISTANCE-Temperature point
-9.0/+9.0 2nd RESISTANCE-Temperature point
-9.0/+9.0 4th RESISTANCE-Temperature point
encapsulated
100.000 ohms
-5.0/+5.0
rod
81349-MILT23648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
2 wire lead
1EA
Rod
Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers
FSC 5905 ⁓ Resistors
Excluding resistance wire.
rod
1. | MILT23648-9 | Cage 81349 |
2. | 347C435H04 | Cage 97942 |
3. | TI-10PCT100OHMSTM1-8 | Cage 01295 |
4. | 347C435H04 | Cage 79500 |
5. | RTH22S101K | Cage 81349 |
Nothing similar to this part number was found in our inventory
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.