Serving our customers with quality and safety first.
not established
solder
1.500in.
1.460in. and 1.580in.
0.360in.
0.022in. and 0.028in.
1.00 watts
25.0 deg celsius
125.0 deg celsius
250.0
10.0
10.00
-15.0 deg celsius 2nd RESISTANCE-Temperature point
-55.0 deg celsius 1st RESISTANCE-Temperature point
0.0 deg celsius 3rd RESISTANCE-Temperature point
100.0 deg celsius 6th RESISTANCE-Temperature point
125.0 deg celsius 7th RESISTANCE-Temperature point
50.0 deg celsius 4th RESISTANCE-Temperature point
75.0 deg celsius 5th RESISTANCE-Temperature point
3.27 kilohms 3rd RESISTANCE-Temperature point
34.0 ohms 7th RESISTANCE-Temperature point
360.0 ohms 4th RESISTANCE-Temperature point
67.5 ohms 6th RESISTANCE-Temperature point
7.38 kilohms 2nd RESISTANCE-Temperature point
100.0 kilohms 1st RESISTANCE-Temperature point
148.0 ohms 5th RESISTANCE-Temperature point
-10.0/+10.0 1st RESISTANCE-Temperature point
-10.0/+10.0 7th RESISTANCE-Temperature point
-3.0/+3.0 3rd RESISTANCE-Temperature point
-3.0/+3.0 4th RESISTANCE-Temperature point
-5.0/+5.0 2nd RESISTANCE-Temperature point
-5.0/+5.0 5th RESISTANCE-Temperature point
-7.0/+7.0 6th RESISTANCE-Temperature point
an/TYQ-23 (v) 1
encapsulated
1.000 kilohms
-1.0/+1.0
25.0
spherical
81349-MIL-T-23648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
2 wire lead
81349-MIL-T-23648/2 government specification
1EA
Spherical
Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers
FSC 5905 ⁓ Resistors
Excluding resistance wire.
Used on an/tyq-23(v)1. spherical
1. | MIL-T-23648/2 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.