Serving our customers with quality and safety first.
not established
1.000in.
0.390in. and 0.420in.
0.125in. and 0.155in.
0.025in.
125.00 milliwatts
100.0 deg celsius
125.0 deg celsius
35.0
2.5
0.70
-25.0 deg celsius 4th RESISTANCE-Temperature point
-50.0 deg celsius 3rd RESISTANCE-Temperature point
-75.0 deg celsius 1st RESISTANCE-Temperature point
-65.0 deg celsius 2nd RESISTANCE-Temperature point
0.0 deg celsius 5th RESISTANCE-Temperature point
100.0 deg celsius 8th RESISTANCE-Temperature point
125.0 deg celsius 9th RESISTANCE-Temperature point
150.0 deg celsius 10th RESISTANCE-Temperature point
50.0 deg celsius 6th RESISTANCE-Temperature point
75.0 deg celsius 7th RESISTANCE-Temperature point
25.3 ohms 6th RESISTANCE-Temperature point
29.3 ohms 7th RESISTANCE-Temperature point
33.7 ohms 8th RESISTANCE-Temperature point
38.9 ohms 9th RESISTANCE-Temperature point
43.9 ohms 10th RESISTANCE-Temperature point
11.9 ohms 1st RESISTANCE-Temperature point
12.8 ohms 2nd RESISTANCE-Temperature point
13.9 ohms 3rd RESISTANCE-Temperature point
16.3 ohms 4th RESISTANCE-Temperature point
18.9 ohms 5th RESISTANCE-Temperature point
-10.3/+10.3 5th RESISTANCE-Temperature point
-12.1/+12.1 6th RESISTANCE-Temperature point
-12.8/+12.8 4th RESISTANCE-Temperature point
-14.3/+14.3 7th RESISTANCE-Temperature point
-14.6/+14.6 3rd RESISTANCE-Temperature point
-15.0/+15.0 2nd RESISTANCE-Temperature point
-16.2/+16.2 8th RESISTANCE-Temperature point
-16.1/+16.1 1st RESISTANCE-Temperature point
-18.5/+18.5 9th RESISTANCE-Temperature point
-20.0/+20.0 10th RESISTANCE-Temperature point
encapsulated
22.000 ohms
-10.0/+10.0
rod
2 wire lead
1EA
Rod
Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers
FSC 5905 ⁓ Resistors
Excluding resistance wire.
rod
1. | TM1-8-22GHM | Cage 01295 |
2. | TM1/8 220K | Cage 01295 |
3. | TM1/8 220K | Cage 96214 |
Nothing similar to this part number was found in our inventory
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.