Datasheet. 20-1089 specification

Reliability Indicator
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.

not established

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.281in. ⁓9/32"

Terminal Surface Treatment
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a terminal surface.

solder

Terminal Length
A measurement of the longest dimension of a terminal,in distinction from width.

12.000in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.375in.

Terminal Diameter
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.

0.020in.

Ambient Temp At Full Rated Power
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.

25.0 deg celsius

Maximum Operating Temp
The maximum temperature at which the item is rated to operate for an extended period of time.

200.0 deg celsius

Thermal Time Constant In Seconds
The time required for the temperature of an item to change 63.2 percent of the difference between its initial and final body temperature when subjected to a temperature change under zero power conditions,expressed in seconds.

22.0

Power Dissipation Constant In Milliwatts Per Deg Celsius
The ratio,at a specified ambient temperature,of a change in power dissipation in an item to the resultant body temperature change,expressed in milliwatts per degree celsius.

1.7

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

-10.0 deg celsius 3rd RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

-30.0 deg celsius 2nd RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

-60.0 deg celsius 1st RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

10.0 deg celsius 4th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

100.0 deg celsius 7th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

125.0 deg celsius 8th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

150.0 deg celsius 9th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

200.0 deg celsius 10th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

40.0 deg celsius 5th RESISTANCE-Temperature point

Temp Points For Resistance Readings At Zero Power
The temperature levels at which resistance ratings have been established,under zero power condition.

70.0 deg celsius 6th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

27.7 kilohms 7th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

344.5 kilohms 5th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

4.9 megohms 3rd RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

5.7 kilohms 9th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

1.5 megohms 4th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

1.6 kilohms 10th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

12.0 kilohms 8th RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

152.3 megohms 1st RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

18.1 megohms 2nd RESISTANCE-Temperature point

Zero Power Resistance At Specified Temp
The resistance at a selected temperature,under zero power condition.

86.7 kilohms 6th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-11.3/+11.3 7th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-11.1/+11.1 2nd RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-12.9/+12.9 8th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-14.3/+14.3 9th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-15.2/+15.2 1st RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-16.8/+16.8 10th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-6.3/+6.3 4th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-6.8/+6.8 5th RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-8.6/+8.6 3rd RESISTANCE-Temperature point

Resistance Tolerance At A Specified Temp In Percent
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.

-9.2/+9.2 6th RESISTANCE-Temperature point

Probe Length
A measurement of the longest dimension of the probe,in distinction from width.

3.000in.

Probe Diameter

0.250in.

Mounting Facility Screw Thread Series Designator
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.

unef

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

encased

Width Across Flats
The shortest straight line between flats,perpendicular to the height.

0.500in. ⁓1/2"

Mounting Thread Quantity
The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.

32 per inch

Zero Power Resistance
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.

680.000 kilohms

Zero Power Resistance Tolerance In Percent At Reference Temp
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.

-5.0/+5.0

Mounting Facility Nominal Screw Thread Diameter
The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.

0.375in.

Reference Temp In Deg Celsius
The temperature at which nominal zero power resistance is specified,expressed in degrees celsius.

25.0

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

probe

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 wire lead

Answers.

What quantity is this sold in?

1EA

What is the style?

Probe

What is the thread length?

0.281 inches

What is the NSN for 20-1089?

5905-00-959-6503

How is this classified for shipping?

Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers

What's the federal classification of 20-1089?

FSC 5905 ⁓ Resistors

Excluding resistance wire.

NSN 5905-00-959-6503 RESISTOR,THERMAL

probe 0.281" thread length

NIIN
009596503
NIIN Date
05/20/66
Schedule B
8533400080 
Name Code
00309
FIIG
A086A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$164.05 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 99931SCEE101-3 Cage 26512
2. 99931SCEE101-3 Cage 26512
3. 99931SCEE101-3 Cage 26512

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 20-1089 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
062960 REOSTATS/PARTS NOI 
UFC (universal freight code)
35140 

Similar by Design Other resistors with similar characteristics

Nothing similar to this part number was found in our inventory

20-1089 / Resistor,thermalWhat is the formal definition of this item?

A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. item may be mounted in a probe or housing. for ballast tube type resistors, see resistor (1), current regulating. excludes transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.