Used on switchboard,p. dpdt; 120.0 volts ac; single phase; 50.0 to 60.0 hertz; input current: 1.0 amps min to 5.0 amps max ac; 10.0 amps max dc; ac output rating: 240.0 volts at 5.0 amps non-inductive; dc output rating: 24.0 volts at 4.0 amps resistive; automatic reset; operate time: 0.2 sec min
Used on switchboard,p. dpdt; 450.0 volts ac; three phase; 50.0 to 60.0 hertz; input current: 1.0 amps min to 5.0 amps max ac; 10.0 amps max dc; dc output rating: 24.0 volts at 4.0 amps resistive; ac output rating: 240.0 volts at 5.0 amps non-inductive; automatic reset; operate time: 0.2 sec min
Used on 4920-01-144-8407 test station,fuel control system compone. contacts: spdt; 3.0 amps at 115.0 volts ac or 1.5 amps at 230.0 volts ac; input voltage: 115.0 or 230.0 volts ac; 50.0 hz min
contact rating: low level to 1.0 amp resistive at 28.0 vdc; contact arrangement: two-pole double throw; terminals: 8 wire hooks; mtd with 4-threaded studs spaced in a rectangular format, thread diameter 0.112 in. thread series 40unc; release time: 15 milliseconds ; time delay on operate 165 to 170 seconds; dimensions: length 1.950 in. , width 1.030 in. , height 1.030 in. ; enclosure: hermetically sealed
Used on ISST. 6control voltage: 90.0 volts ac min to 280.0 volts ac max; output voltage rating: 140.0 volts ac; output current: 25.0 amps nom; contacts: spstno; length: 2.245" min
Used on voltage sensing relay onboard 270 ft wmec coast guard vessels. relay is 240/480 vac, 10 amp close differntial relay adjustment vaiable voltage supply (variac)
Used on torpedo launching control unit. military spdt high power ac/dc; power fet output; break-before-make; cmos; hermetically sealed; 22 pin; oper. output 160vac max; current 2.6 amp max
Used on torpedo launching control unit. military spdt high power ac/dc; power fet output; break-before-make; cmos; hemetically sealed; 22 pin; oper. output 80vdc max; current 4.8 amp max
dpdt; 10.0 amps; polarized; hermetically sealed; solder lug terminals; 1.025 in. max lg; 1.025 in. max w; 1.010 in. max h; three 0.150 in. w mtg slots spaced on the corners of an isosceles triangle spaced 1.396 in. nom l by 0.625 in. nom w; i/p voltage 20 vdc min to 30 vdc max; 500 milliseconds power interrupt
dpdt; 10.0 amps; polorized; hermetically sealed; solder lug terminals; 1.025 in. max lg; 1.025 in. max w; 1.010 in. max h; three 0.150 in. w mtg slots spaced on the corners of an isosceles triangle spaced 1.396 in. nom l by 0.625 in. nom w; i/p voltage 20 vdc min to 30 vdc max; 500 milliseconds power interrupt
minput voltage 12 or 24 volt batt..min. voltage 8 vdc; max. voltage 30 vdc; current rating: 40 ma quiscent (standby) , 12 or 24v; 75a inrush (pull-in) at 12v; 1a maintain (hold-in) at 12v; 37.5 a inrush (pull-in) at 24v
control voltage range: 3.8 to 32.0 vdc; input current: 18.0 ma max at 32.0 vdc; operating temperature range: negative 55.0 degrees celsius to positive 95.0 degrees celsius; dimensions: length 2.000", width 1.000", height 1.100"; mounted by one threaded hole for 0.164-32 screw; terminals spaced 0.880" apart parallel to length
Used on item is a solid state undervoltage relay ac controller p/n 1308d0001-450vac onboard 140 ft wtgb coast guard vessels. relay is a continuous duty cycle with a nylon enclosure; octal type plug mounting; 4 watt max power consumption