Serving our customers with quality and safety first.
dep se dig tp
contact arrangement: spstno; input voltage rating: 3.0 volts dc min and 32.0 volts dc max; output voltage rating: 240.0 volts ac nom; operate time: 0.01 sec max; release time: o.O1 sec max; line frequency range: 47.0 hz min and 63.0 hz mas; terminals: four screw; mounting: two 0.187 inch dia holes placed in an IN-Line configuration spaced 1.875in. c to c parallel to length; over all length: 2.245in. min and 2.285in. max; height: 0.950in. nom
1EA
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
Used on dep se dig tp. contact arrangement: spstno; input voltage rating: 3.0 volts dc min
1. | 240D45 | Cage 55442 |
2. | G240D45 | Cage 95348 |
Nothing similar to this part number was found in our inventory
A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. in lieu of separable contacts and their actuator(s), the switching function is accomplished by means of an arrangement of semiconductors and passive circuit devices. the device is designed to have electrical isolation between control circuit and output circuit. excludes relay, hybrid.