Serving our customers with quality and safety first.
E3 phase power monitor; 3pdt at 10 amp; operating voltage 115 vac at 60 hz; 100/128 voltage sense band; 52/65 frequency sense band; 0.5 sec DROP-Out time delay; 1.0 sec PICK-Up time delay; operating temperature minus 55 deg c to plus 125 deg c; 2.940 in. lg; 2.560 in. w; 3.670 in. h; four 4-40 nc thd studs on 2.250 in. by 1.875 in. mtg center; finish semi gloss blue; connector glass to metal seal, solder hooks; hermetically sealed encapsulated
1EA
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
E3 phase power monitor; 3pdt at 10 amp; operating voltage 115 vac at 60 hz; 100/128 voltage sense band; 52/65 frequency sense band; 0.5 sec drop-out time delay; 1.0 sec pick-up time delay; operating temperature minus 55 deg c to plus 125 deg c; 2.940 in. lg; 2.560 in. w; 3.670 in. h; four 4-40 nc thd studs on 2.250 in. by 1.875 in. mtg center; finish semi gloss blue; connector glass to metal seal, solder hooks; hermetically sealed encapsulated
1. | 100-120 | Cage 15420 |
2. | AE157-015-99 | Cage 55901 |
Nothing similar to this part number was found in our inventory
A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. in lieu of separable contacts and their actuator(s), the switching function is accomplished by means of an arrangement of semiconductors and passive circuit devices. the device is designed to have electrical isolation between control circuit and output circuit. excludes relay, hybrid.