1EN23-6

1EN236 Sensitive Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 1EN23-6 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

bushing mounted

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

1.000in.

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

1.000in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.980in.

Actuator Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.

round

Actuator Diameter
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.

0.250in.

Actuator Height

0.375in.

Actuator Free Position Height

1.375in.

Maximum Voltage Rating In Volts
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.

115.0 ac and 28.0 dc

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

fully inclosed

Mounting Method
The means of attaching the item.

threaded bushing

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.625in. ⁓5/8"

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

2 pole, double throw, one position momentary single switch unit

Switch Release Force
The amount to which the actuating force must be reduced to permit the switch to become unactuated.

64.0 ounces

Switch Actuating Force
The amount of force required to actuate the switch.

192.0 ounces

Actuator Movement
The movement of the switch actuator.

0.040 pretravelin. and 0.250 overtravelin. and 0.020 differentialin.

Contact Load Current Rating At Maximum Rated Voltage
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.

4.000 amperes resistive dc

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unef

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

6 wire lead

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unef

What is the NSN for 1EN23-6?

5930-00-556-0101

How is this classified for shipping?

Schedule B number: 8536509050
nmfc 061300
Switches, slide, for a voltage not exceeding 1,000 v

What's the federal classification of 1EN23-6?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-556-0101 SWITCH,SENSITIVE

unef thread series

NIIN
005560101
NIIN Date
01/01/63
Schedule B
8536509050 
Name Code
00399
FIIG
A053A0
Item Weight
0.200lbs
Item Dimensions
--
QUP
Historical Price
$398.10 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 1EN23-6 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

1EN23-6 / Switch,sensitiveWhat is the formal definition of this item?

A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. includes membrane switch. excludes switch, flexible; switch, pressure; and switch, thermostatic.