SK132653

SK132653 Rotary Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. SK132653 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a 2nd mounting facility

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.250in. 2nd mounting facility ⁓2-1/64"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

5.500in. ⁓5-1/2"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.531in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

3.375in.

Shaft Diameter
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.

0.344in. single actuator

Shaft Length
A measurement of the longest dimension of the shaft,in distinction from width.

0.719in. single actuator

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.266in. 1st mounting facility

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

2.750in. 1st mounting facility

Individual Section Quantity
The number of individual sections included in the item.

4

Switch Contact Basic Design
The general configuration of the contacts of a switch that describes its basic switching structure.

NONPILE-Up nonsymmetrical

Mounting Method
The means of attaching the item.

bracket 1st mounting facility and unthreaded hole 1st mounting facility

Mounting Method
The means of attaching the item.

threaded bushing 2nd mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.562in. 2nd mounting facility ⁓2-1/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line 1st mounting facility

Switch Actuator Indexing Position Quantity
The number of positions to which the switch actuator may be indexed.

3 single actuator

Shaft Type
Indicates the type of shaft included on the item.

round, slotted single actuator

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

tab w/screw

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

first mounting facility is located at front and rear with 4.562 in. lg c to c between mtg holes

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

tap, circuit selector

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf 2nd mounting facility

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unf 2nd mounting facility

What is the style?

Tap, circuit selector

What is the overall width?

3.375 inches

What is the thread length?

0.250 inches 2nd mounting facility

What is the thread class?

2a 2nd mounting facility

What is the NSN for SK132653?

5930-00-311-1849

What's the federal classification of SK132653?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-311-1849 SWITCH,ROTARY

unf 2nd mounting facility thread series tap, circuit selector first mounting facility is located at front 3.375" overall width 5.500" overall length 0.250" 2nd mounting facility thread length 2a 2nd mounting facility thread class

NIIN
003111849
NIIN Date
01/01/63
Schedule B
 
Name Code
02134
FIIG
A052B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$729.40 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 806-M761998/1 Cage 01121

Major End Users Countries and entities

  • - Department of The Navy 
  • - U.s. Coast Guard 
  • - Spain 
  • - Thailand 
  • - Republic of Korea 
  • - Italy 
  • - Denmark 
  • - Greece 
  • - Turkey 

Availability for SK132653 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

SK132653 / Switch,rotaryWhat is the formal definition of this item?

A switch actuated by a definite angular rotation of the switch shaft about its axis. for items having rated actuation travel and pressure characteristics, see switch, sensitive. excludes relay, rotary; switch, stepping; and switch, telephone (as modified).