Serving our customers with quality and safety first.
0.312in. 1st mounting facility ⁓1/64"
0.062in. 2nd mounting facility ⁓2-1/64"
3.067in. and 3.129in. ⁓3-9/64"
1.719in. and 1.781in.
1.719in. and 1.781in.
0.250in. single actuator
0.213in. single actuator and 0.223in. single actuator
0.248in. single actuator and 0.251in. single actuator
0.688in. single actuator
0.531in. at 12:00 o'clock
1
tab at 12:00 o'clock
1.365in. single mounting facility and 1.385in. single mounting facility
NONPILE-Up symmetrical
2 single section front
10 single section front
threaded bushing 1st mounting facility
threaded hole 2nd mounting facility
32 1st mounting facility
32 2nd mounting facility
0.138in. 2nd mounting facility ⁓2-1/64"
0.375in. 1st mounting facility ⁓1/64"
300.0 ac at sea level
30.0 dc at sea level
150.0 degrees from nonturn device single actuator
two position IN-Line 2nd mounting facility
11 single actuator
round, flatted single actuator
tab, solder lug
makes before breaks single section front
15.0 degrees single actuator
fixed stop single actuator
300.0 milliamperes resistive load dc at sea level and 50.0 milliamperes inductive load dc at sea level
50.0 milliamperes resistive load ac at sea level
no detent mechanism - mtg hardware not supplied - shaft extends from rear 1.160 in, is parallel flatted w/ 3rd flat 0.250 in from end
square wafer, panel mount
unc 2nd mounting facility
unef 1st mounting facility
1EA
Unef 1st mounting facility
Unc 2nd mounting facility
Square wafer, panel mount
32 2nd mounting facility
32 1st mounting facility
1.719 inches minimum and 1.781 inches maximum
0.062 inches 2nd mounting facility
0.312 inches 1st mounting facility
Schedule B number: 8536509020
nmfc 061300
Switches, rotary, rated at not over 5 a, for a voltage not exceeding 1,000 v
FSC 5930 ⁓ Switches
Excluding switchgear.
unef 1st mounting facility thread series square wafer, panel mount no detent mechanism - mtg hardware not supplied - shaft extends from rear 1.160 in, is parallel flatted w/ 3rd flat 0.250 in from end 32 2nd mounting facility thread quantity per inch 1.719" overall width 3.067" overall length 0.062" 2nd mounting facility thread length
1. | 2E06A11-1X1045 | Cage 54294 |
2. | 77C708609 | Cage 03538 |
Nothing similar to this part number was found in our inventory
A switch actuated by a definite angular rotation of the switch shaft about its axis. for items having rated actuation travel and pressure characteristics, see switch, sensitive. excludes relay, rotary; switch, stepping; and switch, telephone (as modified).