Datasheet. 505A605G01 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a single mounting facility

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

6.750in. ⁓6-3/4"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

3.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.250in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

2.312in. single mounting facility

Individual Section Quantity
The number of individual sections included in the item.

4

Knob Manufacturer Code
The identifying code of the orginator that controls or manufacturers the knob.

65054

Knob Manufacturer Part Number
The identifying part number assigned to the knob.

310C624H01

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

main propulsion control switchboard part number D-82-3008-3CG-01 onboard 180 ft wlb coast guard vessels

Switch Contact Basic Design
The general configuration of the contacts of a switch that describes its basic switching structure.

coded

Mounting Method
The means of attaching the item.

threaded hole single mounting facility

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

20 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. single mounting facility ⁓1/4"

Contact Voltage Rating In Volts
The voltage for which the contacts are rated,expressed in volts.

300.0 lowest dc voltage rating at sea level

Contact Voltage Rating In Volts
The voltage for which the contacts are rated,expressed in volts.

600.0 highest dc voltage rating at sea level

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position diagonal single mounting facility

Switch Actuator Indexing Position Quantity
The number of positions to which the switch actuator may be indexed.

8 single actuator

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

threaded stud

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

20.0 amperes resistive load dc at sea level and 8.0 amperes resistive load dc at sea level

Contact Arrangement Truth Table
An indication of the configuration of the coded contact switching structure.

decimal, 1 pole - 8 positions each section

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular panel mount

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Answers.

What class is the thread series?

Unc single mounting facility

What is the style?

Rectangular panel mount

What is the thread quantity per inch?

20 single mounting facility

What is the overall width?

2.250 inches

What is the thread class?

2a single mounting facility

What is the NSN for 505A605G01?

5930-01-313-8407

How is this classified for shipping?

Schedule B number: 8536509025
Switches, rotary, rated at over 5 a, for a voltage not exceeding 1,000 volts

What's the federal classification of 505A605G01?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-313-8407 SWITCH,ROTARY

Used on main propulsion control switchboard part number d-82-3008-3cg-01 onboard 180 ft wlb coast guard vessels. unc single mounting facility thread series rectangular panel mount 20 single mounting facility thread quantity per inch 2.250" overall width 6.750" overall length 2a single mounting facility thread class

NIIN
013138407
NIIN Date
01/18/90
Schedule B
8536509025 
Name Code
02134
FIIG
A052B0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
--
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Availability for 505A605G01 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

505A605G01 / Switch,rotaryWhat is the formal definition of this item?

A switch actuated by a definite angular rotation of the switch shaft about its axis. for items having rated actuation travel and pressure characteristics, see switch, sensitive. excludes relay, rotary; switch, stepping; and switch, telephone (as modified).