131702-1

1317021 Rotary Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 131702-1 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.810in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.810in.

Individual Section Quantity
The number of individual sections included in the item.

3

Switch Contact Basic Design
The general configuration of the contacts of a switch that describes its basic switching structure.

NONPILE-Up nonsymmetrical

Mounting Facility Circle Radius
The radius of the circle in which the mounting facilities of an item are located.

1.625in. single mounting facility

Mounting Method
The means of attaching the item.

bracket single mounting facility and threaded hole single mounting facility

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

actuator knob

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

24 single mounting facility

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.190in. single mounting facility ⁓13/64"

Contact Voltage Rating In Volts
The voltage for which the contacts are rated,expressed in volts.

125.0 ac at sea level

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

four position circular single mounting facility

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

zzzy

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

screw

Switch Actuator Positioning Increment
The increments of angular rotation that the switch actuator moves between adjacent index positions.

45.0 degrees single actuator

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

10.0 amperes resistive load ac at sea level

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

item must comply with requirements of defense supply center columbus production standard no. LO4495

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

tap, circuit selector

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc single mounting facility

Reference Number Differentiating Characteristics
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.

breference number differentiating material will be in accordance with naval inventory control point activity hx quality control. manufacturing and testing specifications available at the dla icp.

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc single mounting facility

What is the style?

Tap, circuit selector

What is the thread quantity per inch?

24 single mounting facility

What is the overall width?

2.810 inches

What is the thread class?

2b single mounting facility

What is the NSN for 131702-1?

5930-01-373-9821

How is this classified for shipping?

Schedule B number: 8536509025
nmfc 061300
Switches, rotary, rated at over 5 a, for a voltage not exceeding 1,000 volts

What's the federal classification of 131702-1?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-373-9821 SWITCH,ROTARY

unc single mounting facility thread series tap, circuit selector item must comply with requirements of defense supply center columbus production standard no. LO4495 24 single mounting facility thread quantity per inch 2.810" overall width 2b single mounting facility thread class

NIIN
013739821
NIIN Date
04/13/93
Schedule B
8536509025 
Name Code
02134
FIIG
A052B0
Item Weight
0.000lbs
Item Dimensions
QUP
Historical Price
$670.00 EA
DEMIL / ITAR
USML/ITAR controlled item (Code: F)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. LO4495 Cage 16236

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 131702-1 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

131702-1 / Switch,rotaryWhat is the formal definition of this item?

A switch actuated by a definite angular rotation of the switch shaft about its axis. for items having rated actuation travel and pressure characteristics, see switch, sensitive. excludes relay, rotary; switch, stepping; and switch, telephone (as modified).