395-143-002

395143002 Rotary Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 395-143-002 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.625in. ⁓2-5/8"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

3.530in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.625in.

Mounting Configuration
The pattern or arrangement that describes the mounting configuration of the item.

four 0.196 in. dia mtg holes on 2.125 in. by 2.125 in. mtg centers

Structural Design
The basic structure of the item.

sectional

Ac Operating Voltage Rating In Volts
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.

115.0

Contact Current Type
Indicates the type of current used with the contact/s/.

ac and dc

Contact Maximum Voltage Rating In Volts
The maximum voltage rating at which the contact is rated,expressed in volts.

125.0

Contact Current Rating At Maximum Rated Voltage
The amount of current at maximum rated voltage for which the contact/s/ is designed.

800.0 milliamperes resistive

Contact Maximum Rated Current
The maximum amount of current the contact/s/ will accommodate.

10.0 amperes resistive

Contact Voltage Rating At Maximum Rated Current
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.

115.0

Contact Terminal Quantity
The specific number of contact terminals included.

24

Coil Terminal Quantity
The specific number of coil terminals included.

2

Reset Facility Feature
An indication of whether or not the reset facilities are provided.

not provided

Pull-in Current
The amount of current required to activate the item.

670.0 milliamperes

Hold-in Current
The amount of current required to maintain operation of the item.

150.0 milliamperes

Rotation Direction For Which Designed
The direction of rotation for which the item is designed.

clockwise

Coil Dc Resistance
The opposition that the coil offers to the flow of direct current.

66.0 ohms

Section Quantity
The number of sections included.

2

Coil Winding Quantity
The number of coil winding(s) provided.

1

Shaft Rotation In Deg
The measurement of the shaft rotation,expressed in degrees.

25.0

Criticality Code Justification
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.

feat

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

subsafe

Answers.

What quantity is this sold in?

1EA

What is the overall width?

2.625 inches maximum

What is the NSN for 395-143-002?

5945-01-051-3423

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061300
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of 395-143-002?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-051-3423 RELAY,ROTARY

subsafe 2.625" overall width 2.625" overall length

NIIN
010513423
NIIN Date
11/27/77
Schedule B
8536490075 
Name Code
03890
FIIG
T142-S
Item Weight
0.100lbs
Item Dimensions
26 X 26 X 35
QUP
Historical Price
$1,884.78 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 315-01-005 Cage 58475
2. DA-J15 Cage 71468
3. MDR4096 Cage 7Z941
4. 106.416-7 Cage 77342
5. MDR-134-1 Cage 96169
6. 3-1393139-9 Cage 77342
7. L00267 Cage 16236
8. MDR4096 Cage 77342

Major End Users Countries and entities

  • - Department of The Navy 
  • - U.s. Coast Guard 
  • - Poland 
  • - Spain 
  • - Turkey 

Major End Items End use applications

  • - Elevators, cargo/weapons
  • - Elevators, aircraft
  • - Stream (std. tensioned replenishment at sea method)
  • - Systems, 02n2
  • - Conveyers, fleet vertical package
  • - Los angeles class ssn (688)
  • - Ticonderoga class cg (47)
  • - Spruance class dd (963)
  • - Emory s. land class as
  • - Blue ridge class lcc-19

Availability for 395-143-002 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

395-143-002 / Relay,rotaryWhat is the formal definition of this item?

A relay whose contact arm may rotate through 360 degrees but not in one operation. includes rotary relays which automatically reset. for an item having the dual functions of a switch and a relay assembled together on a common mounting, see relay-switch. excludes switch, rotary; switch, stepping; and switch, telephone (as modified).