11K3404GM

11K3404GM Rotary Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 11K3404GM specification

Torque Load Rating
The ability of an item to withstand a specified torque load without fracture.

52.00 INCH-Ounces

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.250in. ⁓4-1/4"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

4.313in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

4.313in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

dustproof

Mounting Configuration
The pattern or arrangement that describes the mounting configuration of the item.

four 9/32 in. dia mtg holes spaced 3-1/4 in. by 3-1/4 in. c to c

Structural Design
The basic structure of the item.

NONPILE-Up

Ac Operating Voltage Rating In Volts
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.

115.0

Operating Current Rating
The operating current for which the item is rated.

0.4 amperes

Contact Terminal Quantity
The specific number of contact terminals included.

8

Coil Terminal Quantity
The specific number of coil terminals included.

2

Reset Facility Feature
An indication of whether or not the reset facilities are provided.

provided

Pull-in Current
The amount of current required to activate the item.

2.1 amperes

Hold-in Current
The amount of current required to maintain operation of the item.

0.4 amperes

Rotation Direction For Which Designed
The direction of rotation for which the item is designed.

counterclockwise

Coil Dc Resistance
The opposition that the coil offers to the flow of direct current.

10.0 ohms

Contact Arrangement
The designation that identifies the schematic diagram of the contact configuration.

4 pdt

Coil Winding Quantity
The number of coil winding(s) provided.

1

Winding Characteristic
An indication of the characteristic(s) of a winding.

single wound untapped

Coil Pull-in Dc Resistance Rating
The amount of direct current resistance required to activate the coil pull-in.

10.0 ohms

Coil Hold-in Dc Resistance Rating
The amount of direct current resistance required to maintain operation of the coil hold-in.

10.0 ohms

Shaft Rotation In Deg
The measurement of the shaft rotation,expressed in degrees.

25.500

Answers.

What quantity is this sold in?

1EA

What is the overall width?

4.313 inches

What is the NSN for 11K3404GM?

5945-00-636-8700

What's the federal classification of 11K3404GM?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-636-8700 RELAY,ROTARY

4.313" overall width 4.250" overall length

NIIN
006368700
NIIN Date
01/01/63
Schedule B
 
Name Code
03890
FIIG
T142-S
Item Weight
5.000lbs
Item Dimensions
--
QUP
Historical Price
$849.40 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 11K3405G3PC130 Cage 24446
2. 11K3406PC29 Cage 24446
3. 69-1 Cage 77342
4. 676B293PT1 Cage 24446
5. PL533E399PCU3 Cage 24446
6. 904J706PC4 Cage 11660

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 11K3404GM A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

11K3404GM / Relay,rotaryWhat is the formal definition of this item?

A relay whose contact arm may rotate through 360 degrees but not in one operation. includes rotary relays which automatically reset. for an item having the dual functions of a switch and a relay assembled together on a common mounting, see relay-switch. excludes switch, rotary; switch, stepping; and switch, telephone (as modified).