Datasheet. 46-142142P1 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.750in. ⁓2-3/4"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

2.200in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

0.400in. single mounting facility

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.980in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.720in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

glass

Contact Material
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.

nickel

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

6525-01-159-3009 field radiographic/fluoroscopic X-Ray system; model dxd 350 ii

Purpose For Which Designed
The purpose for which the item is designed.

general

Coil Quantity
The number of coils included on the item.

1

Winding Dc Resistance Rating
The measured opposition to the flow of direct current offered by the item winding.

320.0 ohms all windings

Duty Type
Indicates the type of duty provided.

continuous

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 printed circuit terminal single mounting facility

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

1.940 cubicin.

Operating Voltage Rating And Type At Specified Temp
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.

12.0 volts dc 25 deg celsius all windings

Main Contact Load Current Rating At Maximum Rated Voltage
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.

1.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.

12.0 dc

Energizing Element Power Rating
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.

450.0 milliwatts

Precious Material And Location
An indication of the precious material and its location in the item.

contact surfaces gold

Precious Material
Identification of the precious material contained in the item.

gold

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 pin all functions

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.720 inches

What is the NSN for 46-142142P1?

5945-01-224-9044

How is this classified for shipping?

Schedule B number: 8536410020
nmfc 061300
Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v

What's the federal classification of 46-142142P1?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-224-9044 RELAY,REED

Used on 6525-01-159-3009 field radiographic/fluoroscopic x-ray system; model dxd 350 ii. 0.720" overall width 2.750" overall length

NIIN
012249044
NIIN Date
01/24/86
Schedule B
8536410020 
Name Code
30544
FIIG
A03300
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$297.80 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains gold
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. CR120G20A02CB Cage 02295
2. CR120G20A02CB Cage 02295

Major End Users Countries and entities

  • - Department of The Air Force 
  • - Department of The Army 

Availability for 46-142142P1 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

46-142142P1 / Relay,reedWhat is the formal definition of this item?

A relay consisting of an energizing coil and a metallic reed switch mechanism. the reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. it may also include a biasing magnet. the biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. for items in which actuation is dependent on the resonant frequency of the reeds see relay, resonant reed. excludes relay, electromagnetic.