AREA10476

AREA10476 Receptacle Electrical Connector

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. AREA10476 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

angle shape, w/ or w/o cover

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

8.062in. ⁓8-1/16"

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

7.000in.

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

9.875in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

5.893in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

weatherproof

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.438in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
The distance between centerlines of mounting facilities parallel to the width of the item.

4.875in.

Threaded Device Type
Indicates the type of threaded device included on the item.

coupling facility

Mating End Quantity
The number of mating ends provided with the item which are designed to accommodate another connector.

1

Contact Removability
An indication of whether or not the contact(s) is removable.

removable single mating end single contact grouping

Contact Maximum Current Rating In Amps
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.

100.0 single mating end single contact grouping

Polarization Method
The means used to prevent mismating or cross plugging of contacts.

mating end

Shell Type
Indicates the type of shell included on the item.

solid

Connector Locking Method
The means used to secure a connector to its mating counterpart.

externally threaded shell

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

14

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

3.425in. ⁓3-7/16"

Terminal Location
Indicates the location of the terminal/s/ on the item.

back single mating end single contact grouping

Contact Material
The chemical compound or mechanical mixture properties of which the contact is fabricated.

copper alloy single mating end single contact grouping

Contact Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.

tin single mating end single contact grouping

Insert Material
The chemical compound or mechanical mixture properties of which the insert is fabricated.

glass fiber single mating end and plastic polyester single mating end

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

screw single mating end single contact grouping

Shell Material
The chemical compound or mechanical mixture properties of which the shell is fabricated.

aluminum

Shell Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.

paint epoxy

Included Contact Quantity
The number of contacts included with the item which provides electrical connection.

4 single mating end single contact grouping

Included Contact Type
Indicates the type of contact(s) included with the item.

round socket single mating end single contact grouping

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

uns

Answers.

What class is the thread series?

Uns

What is the thread quantity per inch?

14

What is the overall width?

5.893 inches

What is the thread direction?

Right-hand

What is the thread class?

2a

What is the NSN for AREA10476?

5935-00-242-9444

How is this classified for shipping?

Schedule B number: 8538907080
nmfc 061680
Parts suitable for use solely or principally with the apparatus for heading 8535, 8536,8537

What's the federal classification of AREA10476?

FSC 5935 ⁓ Connectors, electrical

Excluding interconnectors, fiber optic

NSN 5935-00-242-9444 CONNECTOR,RECEPTACLE,ELECTRICAL

uns thread series 14 thread quantity per inch 5.893" overall width 8.062" overall length right-hand 2a thread class

NIIN
002429444
NIIN Date
06/03/73
Schedule B
8538907080 
Name Code
15093
FIIG
A039B0
Item Weight
0.000lbs
Item Dimensions
--
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Denmark 

Availability for AREA10476 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061680 ELEC WIRING PLUGS ETC 
UFC (universal freight code)
34570 

Similar by Design Other connectors with similar characteristics

Nothing similar to this part number was found in our inventory

AREA10476 / Connector,receptacle,electricalWhat is the formal definition of this item?

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. it is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. see also wiring harness (as modified) and cable assembly (as modified). for items with termination wires of more than four inches in length, see lead assembly, electrical. for items without inserts, see shell, electrical connector.