61134-26

6113426 Receptacle Electrical Connector

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 61134-26 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

straight shape

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.500in. ⁓1-1/2"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

0.530in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.340in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

1.250in.

Mating End Quantity
The number of mating ends provided with the item which are designed to accommodate another connector.

1

Contact Position Arrangement Style
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.

26 single mating end

Contact Removability
An indication of whether or not the contact(s) is removable.

nonremovable single mating end single contact grouping

Contact Maximum Current Rating In Amps
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.

7.5 single mating end single contact grouping

Polarization Method
The means used to prevent mismating or cross plugging of contacts.

guide pin/socket

Terminal Location
Indicates the location of the terminal/s/ on the item.

back single mating end single contact grouping

Contact Material
The chemical compound or mechanical mixture properties of which the contact is fabricated.

copper alloy single mating end single contact grouping

Contact Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.

gold single mating end single contact grouping and silver single mating end single contact grouping

Insert Material
The chemical compound or mechanical mixture properties of which the insert is fabricated.

plastic single mating end

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

solder well single mating end single contact grouping

Included Contact Quantity
The number of contacts included with the item which provides electrical connection.

26 single mating end single contact grouping

Included Contact Type
Indicates the type of contact(s) included with the item.

round pin single mating end single contact grouping

Precious Material And Weight
An indication of the precious material contained in the item,and the amount per a measurement scale.

0.026 gold grains, troy and 0.026 silver grains, troy

Precious Material
Identification of the precious material contained in the item.

gold and silver

Answers.

What quantity is this sold in?

1EA

What is the overall width?

0.340 inches

What is the NSN for 61134-26?

5935-00-581-3367

How is this classified for shipping?

Schedule B number: 8538907080
nmfc 061680
Parts suitable for use solely or principally with the apparatus for heading 8535, 8536,8537

What's the federal classification of 61134-26?

FSC 5935 ⁓ Connectors, electrical

Excluding interconnectors, fiber optic

NSN 5935-00-581-3367 CONNECTOR,RECEPTACLE,ELECTRICAL

0.340" overall width 1.500" overall length

NIIN
005813367
NIIN Date
01/01/63
Schedule B
8538907080 
Name Code
15093
FIIG
A039B0
QUP
Historical Price
$4.43 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains gold
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 611341-026 Cage 56232
2. SM26-20P Cage 95238
3. 5800332-9531-008 Cage C0426

Major End Users Countries and entities

  • - Brazil 
  • - Spain 
  • - Canada 
  • - New Zealand 
  • - Italy 

Availability for 61134-26 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061680 ELEC WIRING PLUGS ETC 
UFC (universal freight code)
34570 

Similar by Design Other connectors with similar characteristics

Nothing similar to this part number was found in our inventory

61134-26 / Connector,receptacle,electricalWhat is the formal definition of this item?

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. it is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. see also wiring harness (as modified) and cable assembly (as modified). for items with termination wires of more than four inches in length, see lead assembly, electrical. for items without inserts, see shell, electrical connector.