263BP13

263BP13 Pressure-thermostatic Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 263BP13 specification

Capillary Tube Length
A measurement of the longest dimension of a capillary tube.

32.000in.

Bulb Length
A measurement of the longest dimension of a bulb.

1.750in.

Bulb Diameter
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.

0.688in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

gage

Temp Sensing Element Type
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.

capillary TUBE-Bulb

Mounting Method
The means of attaching the item.

base

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

2 pole, single throw, both positions maintained

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

tab w/screw

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

0.250 milliamperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

actuation point adjustable, preset

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

+5.00/+225.00 actuation point pounds per square inch

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

external actuation point knob

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

28.0 dc at sea level single voltage

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

contacts open on pressure increase. close on temperature increase

Answers.

What is the NSN for 263BP13?

5930-00-504-6557

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 263BP13?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-504-6557 SWITCH,PRESSURE-THERMOSTATIC

contacts open on pressure increase. close on temperature increase

NIIN
005046557
NIIN Date
01/01/63
Schedule B
8536509065 
Name Code
13383
FIIG
A048B0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. D165 Cage 78830
2. AC410 Cage 24930

Major End Users Countries and entities

  • - Portugal 
  • - Greece 
  • - Turkey 

Availability for 263BP13 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

263BP13 / Switch,pressure-thermostaticWhat is the formal definition of this item?

A switch which is actuated by changes of pressure (vacuum) on any gas or liquid and by changes in ambient temperature. the contacts for the temperature and pressure sensitive elements may be common.