DA7038-804RANGE3

DA7038804RANGE3 Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. DA7038-804RANGE3 specification

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.125in.

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

5.750in.

Operating Temp Rating
The temperature at which the item operates.

120.0 deg fahrenheit

Mounting Method
The means of attaching the item.

flange

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

30.00 pounds per square inch gage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

12.0 amperes resistive load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

250.0 milliamperes resistive load fifth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

10.0 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

5.0 amperes resistive load third voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

500.0 milliamperes resistive load fourth voltage

Contact Adjustability
The adjustability of the contact.

actuation point adjustable

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

+25.00/+100.00 actuation point degrees fahrenheit

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

external actuation point knob and internal actuation point screw

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

8.00 differential point degrees fahrenheit and 75.00 differential point degrees fahrenheit

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

120.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

120.0 dc at sea level fourth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

240.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

240.0 dc at sea level fifth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

480.0 ac at sea level third voltage

Media For Which Designed
The type of media for which the item is designed.

gas or liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical w/port

Answers.

What is the style?

Cylindrical w/port

What is the NSN for DA7038-804RANGE3?

5930-00-631-3084

How is this classified for shipping?

Schedule B number: 8536509065
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of DA7038-804RANGE3?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-631-3084 SWITCH,PRESSURE

cylindrical w/port

NIIN
006313084
NIIN Date
03/15/75
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

Major End Users Countries and entities

  • - Tennessee Valley Authority 

Availability for DA7038-804RANGE3 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

DA7038-804RANGE3 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.