836T-T302J

836TT302J Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 836T-T302J specification

Inside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.

0.375in. single connection

Hazardous Locations/environmental Protection
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.

dust resistant and moisture resistant

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.500in. ⁓3-1/2"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

7.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

2.500in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

3.500in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.266in.

Longest Horizontal Distance Between Mounting Centers
The longest distance between mounting centers parallel to the horizontal plane.

2.719in.

Longest Vertical Distance Between Mounting Centers
The longest distance between mounting centers parallel to the vertical plane.

2.719in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

gage

Mounting Method
The means of attaching the item.

unthreaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

electrical access port

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

10000.00 pounds per square inch

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.375in. single pressure connection ⁓3/8"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position diagonal

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 two circuit, double break/double make, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

screw

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

100.0 milliamperes resistive load seventh voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

200.0 milliamperes resistive load sixth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

3.0 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

1.2 amperes resistive load fourth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

1.5 amperes resistive load third voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

400.0 milliamperes resistive load fifth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

6.0 amperes resistive load first voltage

Contact Adjustability
The adjustability of the contact.

actuation point adjustable and deactuation point adjustable

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

+0.00/+3000.00 actuation point pounds per square inch and -100.00/+2600.00 deactuation point pounds per square inch

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

external actuation point screw and external deactuation point screw

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 dc at sea level fifth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

120.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

230.0 dc at sea level sixth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

240.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

480.0 ac at sea level third voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

550.0 dc at sea level seventh voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

600.0 ac at sea level fourth voltage

Pressure Connector Type
Indicates the type of pressure connector.

plain, threaded internal single connection

Media For Which Designed
The type of media for which the item is designed.

liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

nptf single pressure connection

Answers.

What class is the thread series?

Nptf single pressure connection

What is the style?

Rectangular

What is the overall width?

2.500 inches

What is the inside diameter?

0.375 inches single connection

What is the NSN for 836T-T302J?

5930-00-631-3262

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 836T-T302J?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-631-3262 SWITCH,PRESSURE

nptf single pressure connection thread series rectangular 2.500" overall width 3.500" overall length 0.375" single connection inside diameter

NIIN
006313262
NIIN Date
03/15/75
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
 
Historical Price
$411.08 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 5011519-01 Cage K1182

Major End Users Countries and entities

  • - Tennessee Valley Authority 
  • - Department of The Navy 
  • - Department of The Air Force 
  • - Australia 

Availability for 836T-T302J A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

836T-T302J / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.