674D8001

674D8001 Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 674D8001 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

3b all threaded hole

Thread Length
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.300in. all threaded hole ⁓5/16"

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.500in. ⁓3-1/2"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.500in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

4.300in.

Longest Horizontal Distance Between Mounting Centers
The longest distance between mounting centers parallel to the horizontal plane.

1.780in.

Shortest Horizontal Distance Between Mounting Centers
The shortest distance between mounting centers parallel to the horizontal plane.

0.890in.

Longest Vertical Distance Between Mounting Centers
The longest distance between mounting centers parallel to the vertical plane.

1.965in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

differential

Operating Temp Rating
The temperature at which the item operates.

-34.0 deg celsius and 71.0 deg celsius

Mounting Method
The means of attaching the item.

threaded hole

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

20 all threaded hole

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

27 all pressure connection

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

4500.00 pounds per square inch

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.125in. single pressure connection ⁓1/8"

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. all threaded hole ⁓1/4"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

isosceles triangle

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

wire lead

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

15.0 amperes resistive load first voltage and 15.0 amperes inductive load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

6.0 amperes resistive load second voltage and 5.0 amperes inductive load second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

28.0 dc at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

480.0 ac at sea level first voltage

Pressure Connector Type
Indicates the type of pressure connector.

plain, threaded internal all connections

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 first voltage and 60.0 first voltage

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

npt all pressure connection

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc all threaded hole

Answers.

What class is the thread series?

Unc all threaded hole

What class is the thread series?

Npt all pressure connection

What is the thread quantity per inch?

27 all pressure connection

What is the thread quantity per inch?

20 all threaded hole

What is the overall width?

4.300 inches

What is the thread length?

0.300 inches all threaded hole

What is the thread class?

3b all threaded hole

What is the NSN for 674D8001?

5930-01-054-4704

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 674D8001?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-054-4704 SWITCH,PRESSURE

unc all threaded hole thread series 27 all pressure connection thread quantity per inch 4.300" overall width 3.500" overall length 0.300" all threaded hole thread length 3b all threaded hole thread class

NIIN
010544704
NIIN Date
01/21/78
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

Major End Users Countries and entities

  • - Greece 

Availability for 674D8001 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

674D8001 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.