581560-2

5815602 Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 581560-2 specification

Inside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.

0.188in. all connections

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.000in. ⁓2-1/64"

Outside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.

0.200in. all connections

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.312in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

0.475in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.125in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.091in. and 0.097in.

Longest Horizontal Distance Between Mounting Centers
The longest distance between mounting centers parallel to the horizontal plane.

0.719in.

Longest Vertical Distance Between Mounting Centers
The longest distance between mounting centers parallel to the vertical plane.

0.719in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

differential

Mounting Method
The means of attaching the item.

base and unthreaded hole

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

10.00 pounds per square inch gage

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

four position rectangular

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, single throw, normally open, momentary action

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

quick disconnect, male

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

20.0 milliamperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

deactuation point not adjustable and actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

0.15 actuation point in. of water

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

30.0 dc at sea level single voltage

Pressure Connector Type
Indicates the type of pressure connector.

barbed, unthreaded external all connections

Media For Which Designed
The type of media for which the item is designed.

liquid

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular

Answers.

What is the style?

Rectangular

What is the overall width?

0.475 inches

What is the outside diameter?

0.200 inches all connections

What is the inside diameter?

0.188 inches all connections

What is the NSN for 581560-2?

5930-01-025-2221

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 581560-2?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-025-2221 SWITCH,PRESSURE

rectangular 0.475" overall width 0.200" all connections outside diameter 2.000" overall length 0.188" all connections inside diameter

NIIN
010252221
NIIN Date
07/29/76
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
30 X 30 X 20
QUP
 
Historical Price
$120.50 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. PSF-100A-20987 Cage 0C579
2. PSF-100A-6068 Cage 0C579
3. PSF-100A-6068 Cage 60423
4. PSF100A6068 Cage 93230
5. PSF-100A-6068 Cage 06141
6. PSF-100A-6068 Cage 60426
7. PSF-100A-20987 Cage 0C579
8. PSF-100A-6068 Cage 0C579
9. PSF-100A-6068 Cage 60423
10. PSF100A6068 Cage 93230
11. PSF-100A-6068 Cage 06141
12. PSF-100A-6068 Cage 60426
13. PSF-100A-20987 Cage 0C579
14. PSF-100A-6068 Cage 0C579
15. PSF-100A-6068 Cage 60423
16. PSF100A6068 Cage 93230
17. PSF-100A-6068 Cage 06141
18. PSF-100A-6068 Cage 60426

Major End Users Countries and entities

  • - Austria 
  • - Spain 
  • - Germany 
  • - Republic of Korea 

Availability for 581560-2 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

581560-2 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.