2D3-1568 PIECE 8

2D31568PIECE8 Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 2D3-1568 PIECE 8 specification

Inside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.

0.250in. single connection

Hazardous Locations/environmental Protection
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.

explosion proof

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

5.460in. ⁓5-15/32"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.500in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.500in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.209in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

1.120in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

gage

Operating Temp Rating
The temperature at which the item operates.

-40.0 deg fahrenheit and 180.0 deg fahrenheit

Mounting Method
The means of attaching the item.

unthreaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

hermetically sealed case

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

7500.00 pounds per square inch gage

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. single pressure connection ⁓1/4"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

2 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

wire lead

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

11.0 amperes resistive load first voltage and 11.0 amperes inductive load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

11.0 amperes resistive load second voltage and 11.0 amperes inductive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

5.0 amperes resistive load third voltage and 3.0 amperes inductive load third voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

500.0 milliamperes resistive load fourth voltage and 250.0 milliamperes inductive load fourth voltage

Contact Adjustability
The adjustability of the contact.

actuation point adjustable and deactuation point adjustable

Contact Adjustment Range
The minimum and maximum limits to which the contact(s) may be adjusted.

+1000.00/+3100.00 actuation point pounds per square inch gage and +700.00/+2800.00 deactuation point pounds per square inch gage

Contact Adjustment Type
Indicates the type of device provided for manual adjustment of the contact(s).

internal actuation point screw

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

125.0 dc at sea level fourth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

250.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

28.0 dc at sea level third voltage

Pressure Connector Type
Indicates the type of pressure connector.

plain, threaded internal single connection

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 first voltage and 60.0 first voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 second voltage and 60.0 second voltage

Media For Which Designed
The type of media for which the item is designed.

gas

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

npt single pressure connection

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Npt single pressure connection

What is the style?

Rectangular

What is the overall width?

1.500 inches

What is the inside diameter?

0.250 inches single connection

What is the NSN for 2D3-1568 PIECE 8?

5930-01-351-5657

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 2D3-1568 PIECE 8?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-351-5657 SWITCH,PRESSURE

npt single pressure connection thread series rectangular 1.500" overall width 5.460" overall length 0.250" single connection inside diameter

NIIN
013515657
NIIN Date
01/10/92
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$278.08 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 232P43CC6 Cage 98087
2. 232P43CC6 Cage 98087

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 2D3-1568 PIECE 8 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

2D3-1568 PIECE 8 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.