Datasheet. 22795 specification

Inside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.

0.125in. single connection

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.542in. ⁓3-35/64"

Outside Diameter
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.

0.213in. single connection and 0.219in. single connection

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.891in.

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

3.219in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

2.324in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.218in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

0.625in.

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

gage

Mounting Method
The means of attaching the item.

bracket and unthreaded hole

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

quick disconnect, male

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

15.0 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

10.0 amperes resistive load first voltage

Contact Adjustability
The adjustability of the contact.

deactuation point not adjustable and actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

2.50 actuation point in. of water and 1.50 deactuation point in. of water and 1.00 differential point in. of water

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

125.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

250.0 ac at sea level first voltage

Media For Which Designed
The type of media for which the item is designed.

gas or liquid

Precious Material And Location
An indication of the precious material and its location in the item.

terminal surfaces silver

Precious Material
Identification of the precious material contained in the item.

silver

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

cylindrical

Answers.

What quantity is this sold in?

1EA

What is the style?

Cylindrical

What is the outside diameter?

0.213 inches minimum single connection and 0.219 inches maximum single connection

What is the inside diameter?

0.125 inches single connection

What is the NSN for 22795?

5930-01-151-4640

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 22795?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-151-4640 SWITCH,PRESSURE

cylindrical 0.213" single connection outside diameter 3.542" overall length 0.125" single connection inside diameter

NIIN
011514640
NIIN Date
04/17/83
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$96.40 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 22795 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

22795 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.