1125P4-2

1125P42 Pressure Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 1125P4-2 specification

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

1.120in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

1.440in. ⁓1-29/64"

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.200in.

Distance Between Mounting Facility Centers
The distance between mounting facility centers.

1.120in.

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

dehydrater filter dscc 01496

Pressure Switch Type
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.

gage

Operating Temp Rating
The temperature at which the item operates.

40.0 deg fahrenheit and 130.0 deg fahrenheit

Mounting Method
The means of attaching the item.

bracket and unthreaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

electrical access port

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

20 single pressure connection

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Proof Pressure
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.

225.00 pounds per square inch gage

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.438in. single pressure connection ⁓29/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

screw

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

1.0 amperes resistive load single voltage

Contact Adjustability
The adjustability of the contact.

deactuation point not adjustable and actuation point not adjustable

Contact Stimulus Rating
The rating of the stimulus required to actuate and/or deactuate the contact(s).

45.00 actuation point pounds per square inch gage and 25.00 deactuation point pounds per square inch gage and 35.00 deactuation point pounds per square inch gage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

115.0 ac at sea level single voltage

Pressure Connector Type
Indicates the type of pressure connector.

plain, threaded external single connection

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf single pressure connection

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unf single pressure connection

What is the thread quantity per inch?

20 single pressure connection

What is the NSN for 1125P4-2?

5930-01-074-1546

How is this classified for shipping?

Schedule B number: 8536509065
nmfc 061300
Switches, for a voltage not exceeding 1000 volts

What's the federal classification of 1125P4-2?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-01-074-1546 SWITCH,PRESSURE

Used on dehydrater filter dscc 01496. unf single pressure connection thread series 20 single pressure connection thread quantity per inch

NIIN
010741546
NIIN Date
03/27/79
Schedule B
8536509065 
Name Code
00206
FIIG
A048B0
Item Weight
0.500lbs
Item Dimensions
--
QUP
Historical Price
$1,935.00 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 6183-22 Cage 01496

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 1125P4-2 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

1125P4-2 / Switch,pressureWhat is the formal definition of this item?

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.