570A750-701-118

570A750701118 Pre Wire Wound Variable Resistor

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 570A750-701-118 specification

Section Quantity
The number of individual elements.

1

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

cylindrical friction mounted

Reliability Indicator
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.

not established

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.218in. ⁓1-7/32"

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

2.000in.

Shaft Diameter
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.

0.250in.

Shaft Length
A measurement of the longest dimension of the shaft,in distinction from width.

0.250in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.968in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

2.375in. ⁓2-3/8"

Shaft Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.

round

Shaft Bearing Type
Indicates the type of shaft bearing/s/ furnished.

ball

Actuator Type
Indicates the type of facility or arrangement provided for moving the variable contact(s).

single shaft

Effective Electrical Rotation In Deg Angular Rotation
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.

350.0

Maximum Starting Torque
The maximum amount of turning force required to initiate the actuator movement.

0.60 INCH-Ounces

Maximum Running Torque
The maximum amount of force requred to maintain actuator movement.

0.60 INCH-Ounces

Shaft End Play
The total axial excursion of the shaft measured at the end of the shaft with a specified axial load applied alternately in the opposite directions.

0.006in.

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately delicate

Terminal Location
The position of the terminal/s/ for making connection to an item.

radially positioned over less than half the circumference

Mounting Method
The means of attaching the item.

clamp ring

Cubic Measure
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

5.396 cubicin.

Electrical Resistance Per Section
A measure of the opposition to the flow of direct or alternating current per section.

100.0 kilohms single section

Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.

175.0 single section and 198.0 single section and 264.0 single section and 290.7 single section

Rotary Actuator Travel In Angular Deg
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.

360.0

Function Conformity Tolerance Per Section
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.

-0.50/+0.50 single section

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.

80.0 single section

Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
A constant that represents the proportionate change in resistance caused by a change in temperature per section,expressed in parts per million per degree celsius.

-150.0/+150.0 single section

Power Dissipation Rating Per Section In Watts
The maximum amount of electrical energy that can be expended per section,expressed in watts.

4.0 free air single section

Function Conformity Per Section
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.

single section independent linearity

Fixed Tap Quantity Per Section
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.

4 single section

Resistance Tolerance Per Section In Percent
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.

-5.0/+5.0 single section

Actuator Travel Control Feature
The feature that controls the actuator travel.

continuous motion

Function Characteristic Per Section
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.

single section linear

Ambient Temp In Deg Celsius Per Section At Full Rated Power
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.

25.0 single section

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

7 turret

Answers.

What quantity is this sold in?

1EA

What is the NSN for 570A750-701-118?

5905-00-895-7648

How is this classified for shipping?

Schedule B number: 8533390080
nmfc 062960
Wirewound variable resistors

What's the federal classification of 570A750-701-118?

FSC 5905 ⁓ Resistors

Excluding resistance wire.

NSN 5905-00-895-7648 RESISTOR,VARIABLE,WIRE WOUND,PRE

1.218" overall length

NIIN
008957648
NIIN Date
02/03/67
Schedule B
8533390080 
Name Code
37408
FIIG
A002A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$66.95 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 570A750-701-118 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
062960 REOSTATS/PARTS NOI 
UFC (universal freight code)
35140 

Similar by Design Other resistors with similar characteristics

Nothing similar to this part number was found in our inventory

570A750-701-118 / Resistor,variable,wire wound,preWhat is the formal definition of this item?

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. the functional tolerance (linearity) of the output is equal to or less than plus or munus 1 percent on linear outputs. specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. for items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable, for items with step by step variation, see rheostat and resistor, step by step. for tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, nonprecision.