9003401

9003401 Plug Electrical Connector

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 9003401 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a and 2b

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand and RIGHT-Hand

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

angle shape, w/o cable clamp

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

2.219in. ⁓2-7/32"

Body Angle In Deg
The angle the end/s/ or legs deviate from the centerline of the inlet end,expressed in degrees.

90.0

Threaded Device Type
Indicates the type of threaded device included on the item.

back shell and coupling facility

Mating End Quantity
The number of mating ends provided with the item which are designed to accommodate another connector.

1

Contact Position Arrangement Style
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.

32-13 single mating end

Contact Removability
An indication of whether or not the contact(s) is removable.

nonremovable single mating end all contact groupings

Contact Maximum Current Rating In Amps
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.

22.0 single mating end 1st contact grouping

Contact Maximum Current Rating In Amps
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.

41.0 single mating end 2nd contact grouping

Contact Maximum Ac Voltage Rating In Volts
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.

900.0 single mating end all contact groupings

Contact Maximum Dc Voltage Rating In Volts
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.

1250.0 single mating end all contact groupings

Polarization Method
The means used to prevent mismating or cross plugging of contacts.

key, multiple key groove

Insert Position In Deg
The amount of clockwise displacement of the indexing radius of the insert from normal position,expressed in degrees.

0.0

Shell Type
Indicates the type of shell included on the item.

solid

Connector Locking Method
The means used to secure a connector to its mating counterpart.

internally threaded coupling ring

Distance From Centerline To Connector End

2.875in.

Distance From Centerline To Cable End

1.875in.

Nominal Thread Length
A nominal measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.

0.438in.

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

18 and 18

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

1.750in. and 2.000in. ⁓2-1/64"

Terminal Location
Indicates the location of the terminal/s/ on the item.

back single mating end all contact groupings

Contact Material
The chemical compound or mechanical mixture properties of which the contact is fabricated.

copper alloy single mating end all contact groupings

Contact Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.

gold single mating end all contact groupings and copper single mating end all contact groupings

Insert Material
The chemical compound or mechanical mixture properties of which the insert is fabricated.

plastic diallyl phthalate single mating end

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

solder well single mating end all contact groupings

Shell Material
The chemical compound or mechanical mixture properties of which the shell is fabricated.

aluminum alloy

Shell Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.

cadmium and chromium

Included Contact Quantity
The number of contacts included with the item which provides electrical connection.

18 single mating end 1st contact grouping

Included Contact Quantity
The number of contacts included with the item which provides electrical connection.

5 single mating end 2nd contact grouping

Included Contact Type
Indicates the type of contact(s) included with the item.

round socket single mating end all contact groupings

Precious Material And Location
An indication of the precious material and its location in the item.

contact surfaces gold

Precious Material And Weight
An indication of the precious material contained in the item,and the amount per a measurement scale.

0.043 gold grains, troy

Precious Material
Identification of the precious material contained in the item.

gold

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

uns and uns

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Uns and uns

What is the thread quantity per inch?

18 and 18

What is the thread direction?

Right-hand and right-hand

What is the thread class?

2a and 2b

What is the NSN for 9003401?

5935-00-581-3847

How is this classified for shipping?

Schedule B number: 8536695050
nmfc 061680
Electrical plugs & sockets, for a voltage not exceeding 1,000 v

What's the federal classification of 9003401?

FSC 5935 ⁓ Connectors, electrical

Excluding interconnectors, fiber optic

NSN 5935-00-581-3847 CONNECTOR,PLUG,ELECTRICAL

uns thread series 18 thread quantity per inch right-hand 2a thread class

NIIN
005813847
NIIN Date
01/01/63
Schedule B
8536695050 
Name Code
01938
FIIG
A039B0
Item Weight
0.800lbs
Item Dimensions
QUP
Historical Price
$12.53 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains gold
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. G243745-41 Cage 70408
2. G243745-41 Cage 64959
3. G243745-41 Cage 01714

Major End Users Countries and entities

  • - Spain 
  • - Republic of Korea 

Availability for 9003401 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Low sensitivity, category iv, aa&e, unclassified 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061680 ELEC WIRING PLUGS ETC 
UFC (universal freight code)
34570 

Similar by Design Other connectors with similar characteristics

Nothing similar to this part number was found in our inventory

9003401 / Connector,plug,electricalWhat is the formal definition of this item?

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. excludes jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. see also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). for items without inserts, see shell, electrical connector.