10048216

10048216 Plug Dummy Connector

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 10048216 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

straight shape, external coupling

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.250in. ⁓2-1/4"

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

0.969in. ⁓31/32"

Threaded Device Type
Indicates the type of threaded device included on the item.

coupling facility

Mating End Quantity
The number of mating ends provided with the item which are designed to accommodate another connector.

1

Contact Removability
An indication of whether or not the contact(s) is removable.

nonremovable single mating end single contact grouping

Contact Maximum Current Rating In Amps
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.

22.0 single mating end single contact grouping

Contact Maximum Ac Voltage Rating In Volts
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.

500.0 single mating end single contact grouping

Contact Maximum Dc Voltage Rating In Volts
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.

700.0 single mating end single contact grouping

Connector Locking Method
The means used to secure a connector to its mating counterpart.

internally threaded coupling nut

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

24

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.625in. ⁓5/8"

Insert Material
The chemical compound or mechanical mixture properties of which the insert is fabricated.

plastic single mating end

Shell Material
The chemical compound or mechanical mixture properties of which the shell is fabricated.

aluminum alloy

Shell Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.

anodize

Included Contact Quantity
The number of contacts included with the item which provides electrical connection.

2 single mating end single contact grouping

Included Contact Type
Indicates the type of contact(s) included with the item.

round socket single mating end single contact grouping

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

contacts shorted together

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unef

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unef

What is the thread quantity per inch?

24

What is the thread direction?

Right-hand

What is the thread class?

2b

What is the NSN for 10048216?

5935-00-755-2937

How is this classified for shipping?

Schedule B number: 8548900100
nmfc 061680
Electrical parts of machinery or apparatus not specified or included elsewhere in chapter 85

What's the federal classification of 10048216?

FSC 5935 ⁓ Connectors, electrical

Excluding interconnectors, fiber optic

NSN 5935-00-755-2937 DUMMY CONNECTOR,PLUG

unef thread series contacts shorted together 24 thread quantity per inch 2.250" overall length right-hand 2b thread class

NIIN
007552937
NIIN Date
01/01/63
Schedule B
8548900100 
Name Code
15094
FIIG
A039B0
QUP
Historical Price
$27.68 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 024-0226-005 Cage 71468
2. 024-226-0005 Cage 71468

Major End Users Countries and entities

  • - Republic of Korea 

Availability for 10048216 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061680 ELEC WIRING PLUGS ETC 
UFC (universal freight code)
34570 

Similar by Design Other dummy connectors with similar characteristics

Nothing similar to this part number was found in our inventory

10048216 / Dummy connector,plugWhat is the formal definition of this item?

An item specifically designed to mate with another connector to perform one or more special functions, such as to act as a cover or shield, to short contacts, or to open or close electrical circuits, in or on another connector. it is not designed for direct attachment to a cable, conduit, or wire, and cannot be used as a connector, plug, electrical. excludes dummy plug, telephone.