801685-7

8016857 Non Wire Wound Variable Resistor

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 801685-7 specification

Section Quantity
The number of individual elements.

1

Shaft Diameter
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.

0.1245in. and 0.1249in.

Shaft Length
A measurement of the longest dimension of the shaft,in distinction from width.

0.500in.

Shaft Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.

round

Shaft Bearing Type
Indicates the type of shaft bearing/s/ furnished.

ball

Actuator Type
Indicates the type of facility or arrangement provided for moving the variable contact(s).

single shaft

Maximum Starting Torque
The maximum amount of turning force required to initiate the actuator movement.

0.25 INCH-Ounces

Shaft Runout
The eccentricity of the shaft diameter with respect to the rotational axis of the shaft,measured at a specified distance from the end of the shaft,when the body of the item is held fixed and the shaft is rotated with a specified load applied radially to the shaft.

0.001in.

Lateral Runout
The perpendicularity of the mounting surface,with respect to the rotational axis of the shaft,and measured on the mounting surface at a specified distance from the outside edge of the mounting surface,when the shaft is held fixed and the body of the item is rotated with specified loads applied radially and axially to the body of the item.

0.001in.

Pilot Diameter Runout
The eccentricity of the pilot diameter with respect to the rotational axis of the shaft and measured on the pilot diameter when the shaft is held and the body of the item is rotated while a specified load is applied radially to the body.

0.00100in.

Mounting Method
The means of attaching the item.

clamp ring

Electrical Resistance Per Section
A measure of the opposition to the flow of direct or alternating current per section.

10.000 kilohms single section

Rotary Actuator Travel In Angular Deg
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.

350.0

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.

125.0 single section

Power Dissipation Rating Per Section In Watts
The maximum amount of electrical energy that can be expended per section,expressed in watts.

1.0 free air single section

Fixed Tap Quantity Per Section
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.

1 single section

Tap Location Tolerance Per Section
The limits of permissible variation from the rated value of the location of a tap per section.

-2.0 to 2.0 deg angular rotation single section

Resistance Tolerance Per Section In Percent
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.

-5.0 to 5.0 single section

Actuator Travel Control Feature
The feature that controls the actuator travel.

stops

Tap Location From Ccw Terminal Per Section In Ohms
Indicates the location of a tap relative to the counterclockwise terminal per section,expressed in ohms.

5000.0 single section

Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius
A constant that represents the proportionate change in resistance of the wire per section of which the resistance element of a resistor is wound,expressed in parts per million per degree celsius.

-20.0 to 20.0 single section

Ambient Temp In Deg Celsius Per Section At Full Rated Power
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.

70.0 single section

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 turret

Answers.

What is the NSN for 801685-7?

5905-00-689-4870

How is this classified for shipping?

Schedule B number: 8533390080
nmfc 062960
Wirewound variable resistors

What's the federal classification of 801685-7?

FSC 5905 ⁓ Resistors

Excluding resistance wire.

NSN 5905-00-689-4870 RESISTOR,VARIABLE,WIRE WOUND,NON

NIIN
006894870
NIIN Date
03/12/71
Schedule B
8533390080 
Name Code
37406
FIIG
A002A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
--
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Availability for 801685-7 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
062960 REOSTATS/PARTS NOI 
UFC (universal freight code)
35140 

Similar by Design Other resistors with similar characteristics

Nothing similar to this part number was found in our inventory

801685-7 / Resistor,variable,wire wound,nonWhat is the formal definition of this item?

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. the functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. for items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. for items with step by step variation, see rheostat and resistor, step by step. for tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.