Serving our customers with quality and safety first.
1
rectangular w/mounting holes
established
0.100
0.535in. ⁓35/64"
6.000in.
0.500in.
0.182in. and 0.197in.
0.090in. and 0.098in.
0.035in.
0.078in.
0.500in.
0.182in. and 0.197in.
0.500in.
round, slotted
single shaft
0.513in. and 0.526in.
2
rear end
unthreaded hole
5.000 kilohms single section
150.0 single section
-50.0/+50.0 single section
0.75 free air single section
-5.0/+5.0 single section
85.0 single section
a single section
81349-MILR39015/2 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
3 wire lead
1EA
0.182 inches minimum and 0.197 inches maximum
Schedule B number: 8533390080
nmfc 062960
Wirewound variable resistors
FSC 5905 ⁓ Resistors
Excluding resistance wire.
0.182" overall width 0.535" overall length
1. | M39015/02-006LP | Cage 81349 |
2. | RT22C2L502 | Cage 81349 |
3. | M39015/2-006LP | Cage 81349 |
4. | MIL-R-39015-2 | Cage 81349 |
5. | RTR22DL502P | Cage 81349 |
6. | 11141-0046 | Cage 27914 |
7. | 4005692-7 | Cage 07187 |
8. | 3250L501-502 | Cage 80294 |
9. | 533199-22 | Cage 96214 |
10. | 1450022-2 | Cage 93346 |
11. | 381-0007-110 | Cage 95105 |
12. | 3255L502 | Cage 32997 |
13. | 325L-1-502 | Cage 32997 |
14. | 381-1721-120 | Cage 94987 |
15. | 3250L466-502 | Cage 80294 |
16. | 576R671H47 | Cage 97942 |
17. | 300-00HS5K0HMS | Cage 94271 |
18. | 300-00HS5K0HMS | Cage 0EBU2 |
19. | M39015/2-006LM | Cage 81349 |
Nothing similar to this part number was found in our inventory
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. the functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. for items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. for items with step by step variation, see rheostat and resistor, step by step. for tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.