CPP3367

CPP3367 Meter Movement Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. CPP3367 specification

Terminal Quantity
The number of terminals for providing electrical connection to the item.

4

Terminal Type
Indicates the type of terminals for providing electrical connection to the item.

wire hook

Scale Unit Of Measure Inscription
The standard of valuation as represented by the inscription.

w

Scale Linearity
Equal or unequal distances between graduations representing values of measurement on a scale.

nonlinear

Scale Division Quantity
The number of scale divisions.

39

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Inscription Background Color
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.

white

Mounting Configuration
The pattern or arrangement that describes the mounting configuration of the item.

three no. 4/0.112 in./-40 thd mtg studs spaced 120 deg apart

Voltage Rating
The value(s) of potential for which the item is rated.

125.0 volts

Scale Measurement Range
The minimum and maximum numeric values representing the measurement coverage of a scale.

+0.0/+2.0

Main Contact Arrangement
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.

1 pole, single throw, both positions maintained

Main Contact Current Type
Indicates the type of current used by the main contact/s/.

dc

Main Contact Current Rating
The current rating of the main contact/s/.

25.0 milliamperes

Meter Movement Current Type
Indicates the type of current used in the meter movement.

dc

Meter Movement Current Range
An indication of the minimum and maximum amount of current used in the meter movement.

+0.0/+50.0 microamperes

Meter Movement Range Direction
An indication of the direction of the meter movement reading range.

left to right

Dial Scale Marking Color
The hue or tint of the dial scale marking(s).

black

Err Default
An indication of whether or not the luminous scale marking/s/ are activated by ultraviolet.

err default

Meter Mounting Type
Indicates the type of mount utilized to support the meter.

flush

Contact Closing Condition
An indication of the specific condition that causes the contacts to close.

decrease value

Reset Facility Feature
An indication of whether or not the reset facilities are provided.

provided

Lock In Device Type
Indicates the type of lock in device provided.

coil

Release Method
The means by which the item is released.

deenergize LOCK-In coil

Err Default
A measurement between specified points of the meter to the panel, in distinction from height.

err default

Meter Depth Behind Mounting Flange
A measurement between the mounting flange and the extremity of the meter, indistinction from height.

1.625in.

Mounting Flange Diameter
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.

2.800in.

Meter Body Diameter
The length of a straight line which passes through the center of the meter body and terminates at the circumference.

2.800in.

Err Default
A measurement of the longest dimension of the meter body,in distinction from width.

err default

Answers.

What quantity is this sold in?

1EA

What is the NSN for CPP3367?

5945-00-402-1674

How is this classified for shipping?

Schedule B number: 8536490075
nmfc 061700
Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of CPP3367?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-402-1674 RELAY,METER MOVEMENT

NIIN
004021674
NIIN Date
04/08/70
Schedule B
8536490075 
Name Code
03884
FIIG
T142-K
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$310.35 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 25-1832-1521 Cage 80145

Major End Users Countries and entities

  • - Defense Logistics Agency 

Availability for CPP3367 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061700 ELEC APPLIANCES/INSTRUMENTS NOI 
UFC (universal freight code)
34580 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

CPP3367 / Relay,meter movementWhat is the formal definition of this item?

A relay which operates by means of a d'arsonval or similar meter type actuation.