Datasheet. FP-2T-01-005 ITEM 42 specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

9.000in. ⁓9-1/64"

Power Cable Length
The length measured from the element to the extreme end of the power cable.

24.000in.

Ac Voltage Rating
The value,or range of values,of root mean square potential for which the item is rated.

115.000 volts

Ac Voltage Rating
The value,or range of values,of root mean square potential for which the item is rated.

230.000 volts

Frequency Rating
The number of complete cyclic changes,per unit of time,for which an item is rated.

60.000 hertz

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

1.250in. ⁓1-1/4"

Actuation Method
The means by which the item is actuated.

buoyancy

Electrical Connection Type
Indicates the type of electrical connection included on the item.

cable

Internal Battery Accommodation
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.

not included

Current Rating At Maximum Rated Voltage
The amount of current at maximum rated voltage for which the item is designed.

10.0 amperes resistive load

Float Quantity
The number of floats provided.

1

Operating Temp Rating
The temperature at which the item operates.

-65.0 deg fahrenheit and 125.0 deg fahrenheit

Mounting Method
The means of attaching the item.

thread

Mounting Position
The installed position for which the item is designed.

vertical to 45 deg angle mtg position

Contact Arrangement
The designation that identifies the schematic diagram of the contact arrangement.

spst normally open

Relay
An indication of whether or not a relay is included.

not included

Liquid Type For Which Designed
Indicates the type of liquid(s) for which the item is designed.

lubricating oil

Float Effective Travel
The distance of the effective travel of the float.

0.250in.

Mounting Dimensions
The mounting dimensions of the item.

mtg by 1-1/4 in. npt thd connection

Tank Insertion Length
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.

8.000in.

Extra Long Reference Number
A reference number exceeding 32 positions.

LS-800-2-SS-BN-SPST-100-GR1-1, lo=8.75-L1=6.75nc, c

Phase
The number of alternating current phases.

single

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

float is reversible on stem to select normally open or normally closed position

Fsc Application Data
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.

switch, float, liquid level, except engine

Reference Number Differentiating Characteristics
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.

as differentiated by operating temp rating, float quantity, mounting method and tank insertion length

Answers.

What quantity is this sold in?

1EA

What is the NSN for FP-2T-01-005 ITEM 42?

5930-00-852-2565

How is this classified for shipping?

Schedule B number: 8413919520
nmfc 061300
Parts, of pumps for liquids

What's the federal classification of FP-2T-01-005 ITEM 42?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-852-2565 SWITCH,LIQUID LEVEL

float is reversible on stem to select normally open or normally closed position 9.000" overall length

NIIN
008522565
NIIN Date
01/01/62
Schedule B
8413919520 
Name Code
37187
FIIG
T109-D
Item Weight
1.300lbs
Item Dimensions
100 X 100 X 30
QUP
Historical Price
$1,280.05 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. LS800 Cage 04034
2. 800 Cage 04034
3. LS-800-2-SS-BN-SPST-100-GR1-1, - Cage 09959

Major End Users Countries and entities

  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - Department of The Navy 
  • - Poland 
  • - Spain 
  • - Australia 
  • - Republic of Korea 
  • - Italy 
  • - Turkey 

Availability for FP-2T-01-005 ITEM 42 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

FP-2T-01-005 ITEM 42 / Switch,liquid levelWhat is the formal definition of this item?

A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. used in conjunction with pumps or valves to transfer liquid from one source to another. it may include a relay controlled by the switch element. excludes transmitter, liquid quantity.