11040501-153

11040501153 Induct Wire Wound Fixed Resistor

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 11040501-153 specification

Temp Coefficient Of Resistance In Ppm Per Deg Celsius
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.

-20.0/+20.0

Electrical Resistance
A measure of the opposition to the flow of electrical current.

1.000 kilohms

Resistance Tolerance In Percent
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.

-1.000/+1.000

Ambient Temp In Deg Celsius At Full Rated Power
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.

25.0

Ambient Temp In Deg Celsius At Zero Percent Rated Power
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.

275.0

Temp Range Of Temp Coefficient In Deg Celsius
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.

-55.0/+275.0

Inclosure Method
The means provided to coat,cover,or protect the item.

encapsulated

Terminal Type
Indicates the type of terminals for providing electrical connection to the item.

wire lead

Reliability Indicator
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.

established

Reliability Failure Rate Level In Percent
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.

0.001

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

0.063in. and 0.125in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.375in. and 0.437in.

Power Dissipation Rating In Watts
The maximum amount of electrical energy that can be expended by an item,expressed in watts.

2.000 free air

Cubic Measure (non-core)
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.

0.004 cubicin.

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

axial terminal each end

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-39007 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-39007/8 government specification

Answers.

What quantity is this sold in?

1EA

What is the style?

Axial terminal each end

What is the NSN for 11040501-153?

5905-00-513-2874

How is this classified for shipping?

Schedule B number: 8533390080
nmfc 062960
Wirewound variable resistors

What's the federal classification of 11040501-153?

FSC 5905 ⁓ Resistors

Excluding resistance wire.

NSN 5905-00-513-2874 RESISTOR,FIXED,WIRE WOUND,INDUCT

axial terminal each end

NIIN
005132874
NIIN Date
08/03/74
Schedule B
8533390080 
Name Code
37403
FIIG
A001A0
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$2.00 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
Has ESD sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. RW80U1001F Cage 81349
2. RWP19F1001F Cage 81349
3. RWR8051001FR Cage 81349
4. RWR8051001FS Cage 81349
5. RWR70S1001FM Cage 81349
6. RWR80S1001FS Cage 81349
7. MIL-R-39007/8 Cage 81349
8. C95044-1000-3481 Cage 04274
9. RS1B1K1PCT Cage 91637
10. 4008217-385 Cage 07187
11. 538216-1385 Cage 96214
12. RS1AU00B10000H Cage 91637
13. 443-1502-110 Cage 94756
14. 443-1502-299 Cage 94756
15. 884-90048-019 Cage 96182
16. TS1W1000-1 Cage 15915
17. G210000H Cage 91637
18. 83290-1001Z4B Cage 26916
19. 443-0825-038 Cage 94756
20. 443-0955-385 Cage 94756
21. 1100S1-0KP0RM1PCT Cage 00213
22. S1A1-0KP0RM1PCT Cage 06416
23. SA15-1-0KP0RM1PCT Cage 53655
24. RS1B4-1-0KP0RM1PCT Cage 91637
25. AK1000NSM1000-3 Cage 00213
26. GN3-6-1001H Cage 91637
27. SPF-102K Cage 75042
28. 4706-650085 Cage 89536
29. 650085 Cage 89536
30. BWF-102K Cage 75042

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - National Security Agency 
  • - U.s. Coast Guard 
  • - Austria 
  • - Poland 
  • - Bulgaria 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Australia 
  • - Belgium 
  • - Canada 
  • - New Zealand 
  • - France 
  • - Germany 
  • - Republic of Korea 
  • - United Kingdom 
  • - Netherlands 
  • - Portugal 
  • - Italy 
  • - Norway 
  • - Greece 
  • - Turkey 

Availability for 11040501-153 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
Electrostatic sensitive device (esd) 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
062960 REOSTATS/PARTS NOI 
UFC (universal freight code)
35140 

Similar by Design Other resistors with similar characteristics

Nothing similar to this part number was found in our inventory

11040501-153 / Resistor,fixed,wire wound,inductWhat is the formal definition of this item?

Inc 37403 reinstated on 010303~a resistor whose ohmic value cannot be adjusted or varied. the resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. the item must have inherent characteristics of inducing self-inductance. opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. excludes suppressor, ignition interference. see also resistor (1), fixed, wire wound, noninductive.