YMA3412D(108/118)(380/420)(.250-

YMA3412D108118380420250 Hybrid Relay

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. YMA3412D(108/118)(380/420)(.250- specification

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

3.940in. ⁓3-61/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

2.000in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

3.171in.

Operating Temp Range
The minimum and maximum limits of temperature at which the item is rated for operation.

-55.0/+125.0 deg celsius

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

power dist assy, loral corp

Voltage Rating
The value(s) of potential for which the item is rated.

108.0 volts operate and 118.0 volts operate

Contact Arrangement
The designation that identifies the schematic diagram of the contact configuration.

double pole, double throw

Current Rating
The amount of current for which the item is designed.

10.00 amperes resistive

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

moisture resistant and shock resistant and vibration resistant

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

250.00 milliseconds operate

Time Delay
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.

250.00 milliseconds TURN-Off

Extra Long Reference Number
A reference number exceeding 32 positions.

YMA3412D (108/118) (380/420) (.250/.250) 115

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

16 pin

Reference Number Differentiating Characteristics
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.

as differentiated by extra long reference number

Answers.

What quantity is this sold in?

1EA

What is the overall width?

3.171 inches

What is the NSN for YMA3412D(108/118)(380/420)(.250-?

5945-01-421-0549

How is this classified for shipping?

Schedule B number: 8536490080
nmfc 061300
Relays, for a voltage exceeding 60 v but not exceeding 1,000 v

What's the federal classification of YMA3412D(108/118)(380/420)(.250-?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-421-0549 RELAY,HYBRID

Used on power dist assy, loral corp. 3.171" overall width 3.940" overall length

NIIN
014210549
NIIN Date
10/31/95
Schedule B
8536490080 
Name Code
31445
FIIG
A513L0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$6,074.35 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 100-500 Cage 15420
2. ES7472-02 Cage 20418

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Air Force 

Availability for YMA3412D(108/118)(380/420)(.250- A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other relays with similar characteristics

Nothing similar to this part number was found in our inventory

YMA3412D(108/118)(380/420)(.250- / Relay,hybridWhat is the formal definition of this item?

A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. it consists of a combination of semiconductor and passive circuit devices, which in turn control an integral electro-magnetic relay. excludes relays which employ diodes, rectifiers or other passive devices to achieve contact protection or coil modification. excludes relay, solid state.