Serving our customers with quality and safety first.
-65.0/+125.0 deg celsius
double pole, double throw
hermetically sealed
A81348-MIL-R-28776 test data document; 5 vdc supply voltage; 50 ohms coil resistance; 0.75 ma max rated TURN-On current; 0.3 vdc max rated TURN-Off voltage; 15 ma max control signal current; 82.2/112.1 ma max coil current; 1 amp at 28 vdc resistive; 0.10 amp at 28 vdc lamp; 9 wire lead terminals; 0.370 in. min terminal lg; electromechanical output; terminal mtd; failure rate 1.0 pct
Schedule B number: 8536410030
nmfc 061300
Relays, except electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v
FSC 5945 ⁓ Relays and solenoids
Excluding contractors.
A81348-mil-r-28776 test data document; 5 vdc supply voltage; 50 ohms coil resistance; 0.75 ma max rated turn-on current; 0.3 vdc max rated turn-off voltage; 15 ma max control signal current; 82.2/112.1 ma max coil current; 1 amp at 28 vdc resistive; 0.10 amp at 28 vdc lamp; 9 wire lead terminals; 0.370 in. min terminal lg; electromechanical output; terminal mtd; failure rate 1.0 pct
1. | MIL-PRF-28776/1 | Cage 81349 |
2. | MIL-R-28776/1 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. it consists of a combination of semiconductor and passive circuit devices, which in turn control an integral electro-magnetic relay. excludes relays which employ diodes, rectifiers or other passive devices to achieve contact protection or coil modification. excludes relay, solid state.