Datasheet. S5377 specification

Operating Temp Rating
The temperature at which the item operates.

200.0 deg fahrenheit

Mounting Method
The means of attaching the item.

line

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

electrical access port

Contact Action Stimulus
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.

increase

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

1 pole, double throw, one position momentary

Terminal Type
Indicates the type of terminal for providing electrical connection to the item.

screw

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

20.0 amperes resistive load first voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

20.0 amperes resistive load second voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

20.0 amperes resistive load third voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

250.0 milliamperes resistive load fifth voltage

Contact Load Current Rating
The amount of current that the contacts are rated to make or break with a specified load.

500.0 milliamperes resistive load fourth voltage

Contact Adjustability
The adjustability of the contact.

actuation point not adjustable

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

125.0 ac at sea level first voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

125.0 dc at sea level fourth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

250.0 ac at sea level second voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

250.0 dc at sea level fifth voltage

Contact Voltage Rating In Volts
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.

480.0 ac at sea level third voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 first voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 second voltage

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 third voltage

Media For Which Designed
The type of media for which the item is designed.

liquid

Answers.

What quantity is this sold in?

1EA

What is the NSN for S5377?

5930-00-055-9385

How is this classified for shipping?

Schedule B number: 9026107000
nmfc 061300
Instruments and apparatus for measuring or checking the flow or level of liquids

What's the federal classification of S5377?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-055-9385 SWITCH,FLOW

NIIN
000559385
NIIN Date
01/01/63
Schedule B
9026107000 
Name Code
36841
FIIG
A048B0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$140.03 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 2600-0911-1-2IN Cage 90800

Major End Users Countries and entities

  • - Department of The Navy 

Availability for S5377 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

S5377 / Switch,flowWhat is the formal definition of this item?

A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.